Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 287

The DOI matches its Crossref record; 81 of the 81 references it cites were found in a registry or an index.

Bioimaging of metals by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS)

Becker, J. Sabine, Zoriy, Miroslav, Matusch, Andreas, Wu, Bei, Salber, Dagmar, Palm, Christoph, Becker, J. Susanne·2010·Mass Spectrometry Reviews

Abstract

The distribution analysis of (essential, beneficial, or toxic) metals (e.g., Cu, Fe, Zn, Pb, and others), metalloids, and non‐metals in biological tissues is of key interest in life science. Over the past few years, the development and application of several imaging mass spectrometric techniques has been rapidly growing in biology and medicine. Especially, in brain research metalloproteins are in the focus of targeted therapy approaches of neurodegenerative diseases such as Alzheimer's and Parkinson's disease, or stroke, or tumor growth. Laser ablation inductively coupled plasma mass spectrometry (LA‐ICP‐MS) using double‐focusing sector field (LA‐ICP‐SFMS) or quadrupole‐based mass spectrometers (LA‐ICP‐QMS) has been successfully applied as a powerful imaging (mapping) technique to produce quantitative images of detailed regionally specific element distributions in thin tissue sections of human or rodent brain. Imaging LA‐ICP‐QMS was also applied to investigate metal distributions in plant and animal sections to study, for example, the uptake and transport of nutrient and toxic elements or environmental contamination. The combination of imaging LA‐ICP‐MS of metals with proteomic studies using biomolecular mass spectrometry identifies metal‐containing proteins and also phosphoproteins. Metal‐containing proteins were imaged in a two‐dimensional gel after electrophoretic separation of proteins (SDS or Blue Native PAGE). Recent progress in LA‐ICP‐MS imaging as a stand‐alone technique and in combination with MALDI/ESI‐MS for selected life science applications is summarized. © 2009 Wiley Periodicals, Inc., Mass Spec Rev 29:156–175, 2010

Overview

Integrity signals

Registry

Crossref · 10.1002/mas.20239

Cites

81 of 81 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 81 references

Cited by

See all 287

Metadata

Authors
Becker, J. S., Zoriy, M., Matusch, A., Wu, B., Salber, D., Palm, C., & Becker, J. S.
Venue
Mass Spectrometry Reviews
Publisher
Wiley
Published
2009-06-25
Volume
29
Issue
1
Pages
156-175
ISSN
  • 0277-7037
  • 1098-2787
Cited by
287
References
81
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bioimaging of metals by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). https://app.cochat.ai/papers/10.1002/mas.20239
The paper
Becker, J. S., Zoriy, M., Matusch, A., Wu, B., Salber, D., Palm, C., & Becker, J. S. (2010). Bioimaging of metals by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Mass Spectrometry Reviews. https://doi.org/10.1002/mas.20239

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.