The DOI matches its Crossref record.
Stable-Isotope Dimethylation Labeling Combined with LC−ESI MS for Quantification of Amine-Containing Metabolites in Biological Samples
Abstract
One of the challenges associated with metabolome profiling in complex biological samples is to generate quantitative information on the metabolites of interest. In this work, a targeted metabolome analysis strategy is presented for the quantification of amine-containing metabolites. A dimethylation reaction is used to introduce a stable isotopic tag onto amine-containing metabolites followed by LC-ESI MS analysis. This labeling reaction employs a common reagent, formaldehyde, to label globally the amine groups through reductive amination. The performance of this strategy was investigated in the analysis of 20 amino acids and 15 amines by LC-ESI MS. It is shown that the labeling chemistry is simple, fast (<10-min reaction time), specific, and provides high yields under mild reaction conditions. The issue of isotopic effects of the labeled amines on reversed-phase (RP) and hydrophilic interaction (HILIC) LC separations was examined. It was found that deuterium labeling causes an isotope effect on the elution of labeled amines on RPLC but has no effect on HILIC LC. However, 13C-dimethylation does not show any isotope effect on either RPLC or HILIC LC, indicating that 13C-labeling is a preferred approach for relative quantification of amine-containing metabolites in different samples. The isotopically labeled 35 amine-containing analogues were found to be stable and proved to be effective in overcoming matrix effects in both relative and absolute quantification of these analytes present in a complicated sample, human urine. Finally, the characteristic mass difference provides additional structural information that reveals the existence of primary or secondary amine functional groups in amine-containing metabolites. As an example, for a human urine sample, a total of 438 pairs of different amine-containing metabolites were detected, at signal-to-noise ratios of greater than 10, by using the labeling strategy in conjunction with RP LC-ESI Fourier-transform ion cyclotron resonance MS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Multiplex peptide stable isotope dimethyl labeling for quantitative proteomics
Boersema, P. J., Raijmakers, R., Lemeer, S., Mohammed, S., & Heck, A. J. R. (2009) · Nature Protocols · doi:10.1038/nprot.2009.21 · Cited by 1,357
Scalbert, A., Brennan, L., Fiehn, O., Hankemeier, T., Kristal, B. S., van Ommen, B., Pujos-Guillot, E., Verheij, E., Wishart, D., & Wopereis, S. (2009) · Metabolomics · doi:10.1007/s11306-009-0168-0 · Cited by 565
Mass Spectrometry Strategies in Metabolomics
Lei, Z., Huhman, D. V., & Sumner, L. W. (2011) · Journal of Biological Chemistry · doi:10.1074/jbc.r111.238691 · Cited by 481
Mass spectrometric based approaches in urine metabolomics and biomarker discovery
Khamis, M. M., Adamko, D. J., & El‐Aneed, A. (2017) · Mass Spectrometry Reviews · doi:10.1002/mas.21455 · Cited by 342
Advances in metabolite identification
Wishart, D. S. (2011) · Bioanalysis · doi:10.4155/bio.11.155 · Cited by 284
Metadata
- Authors
- Guo, K., Ji, C., & Li, L.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-10-10
- Volume
- 79
- Issue
- 22
- Pages
- 8631-8638
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2001385996
- Cited by
- 169
- References
- 0
- FWCI
- 2.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stable-Isotope Dimethylation Labeling Combined with LC−ESI MS for Quantification of Amine-Containing Metabolites in Biological Samples. https://app.cochat.ai/papers/10.1021/ac0704356
- The paper
- Guo, K., Ji, C., & Li, L. (2007). Stable-Isotope Dimethylation Labeling Combined with LC−ESI MS for Quantification of Amine-Containing Metabolites in Biological Samples. Analytical Chemistry. https://doi.org/10.1021/ac0704356
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.