The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Continuous-Flow Particle Separation by 3D Insulative Dielectrophoresis Using Coherently Shaped, dc-Biased, ac Electric Fields
Abstract
We present the development of a continuous-flow, "dielectrophoretic spectrometer" based on insulative DEP techniques and three-dimensional geometric design. Hot-embossed thermoplastic devices allow for high-throughput analysis and geometric control of electric fields via ridged microstructures patterned in a high width-to-depth aspect ratio (250:1) channel. We manipulate particles with dc-biased, ac electric fields and generate continuous-output streams of particles with a transverse outlet position specified by linear and nonlinear particle mobilities. We show, with simulation and experiment, that characteristic shape factors can be defined that capture the effects of constrictions in channel depth and that modulating the angle of these constrictions changes the resulting local DEP force. Microdevices are fabricated with an insulative constriction in channel depth, whose angle of incidence with the direction of flow varies continuously across the channel width. The resulting electric field gradients enable demonstration of a dielectrophoretic spectrometer that separates particles and controls their transverse channel position.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jones, T. B. (1995) · doi:10.1017/cbo9780511574498 · Cited by 2,786
Cited by
Continuous flow separations in microfluidic devices
Pamme, N. (2007) · Lab on a Chip · doi:10.1039/b712784g · Cited by 770
Dielectrophoresis in microfluidics technology
Çetin, B., & Li, D. (2011) · ELECTROPHORESIS · doi:10.1002/elps.201100167 · Cited by 411
Gleghorn, J. P., Pratt, E. D., Denning, D., Liu, H., Bander, N. H., Tagawa, S. T., Nanus, D. M., Giannakakou, P. A., & Kirby, B. J. (2010) · Lab Chip · doi:10.1039/b917959c · Cited by 396
Self-citationDielectrophoresis for manipulation of micro/nano particles in microfluidic systems
Zhang, C., Khoshmanesh, K., Mitchell, A., & Kalantar-zadeh, K. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2922-6 · Cited by 305
Isolation of Circulating Tumor Cells by Dielectrophoresis
Gascoyne, P., & Shim, S. (2014) · Cancers · doi:10.3390/cancers6010545 · Cited by 275
Metadata
- Authors
- Hawkins, B. G., Smith, A. E., Syed, Y. A., & Kirby, B. J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-09-01
- Volume
- 79
- Issue
- 19
- Pages
- 7291-7300
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1987873283
- Cited by
- 162
- References
- 1
- FWCI
- 8.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous-Flow Particle Separation by 3D Insulative Dielectrophoresis Using Coherently Shaped, dc-Biased, ac Electric Fields. https://app.cochat.ai/papers/10.1021/ac0707277
- The paper
- Hawkins, B. G., Smith, A. E., Syed, Y. A., & Kirby, B. J. (2007). Continuous-Flow Particle Separation by 3D Insulative Dielectrophoresis Using Coherently Shaped, dc-Biased, ac Electric Fields. Analytical Chemistry. https://doi.org/10.1021/ac0707277
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.