The DOI matches its Crossref record.
Rapid Screening of Anabolic Steroids in Urine by Reactive Desorption Electrospray Ionization
Abstract
Fast screening for anabolic steroids in whole urine is achieved by combining reactive desorption electrospray ionization (reactive DESI) and tandem mass spectrometry. Spray solutions containing hydroxylamine allow heterogeneous reactions of hydroxylamine with the carbonyl group of the steroids during the ionization process. Seven steroids, including a glycosteroid, were examined. The ion/molecule reaction adduct and the oxime formed via its dehydration were observed using reactive DESI; the protonated and sodiated forms of the ionized steroid were also observed both in reactive DESI and in DESI performed without the added hydroxylamine reagent. Paper, glass, and polytetrafluoroethylene were tested as sample substrates, but the glycosteroid was ionized intact without hydrolysis only from polytetrafluoroethylene. Limits of detection for the pure compounds were less than 1 ng, dynamic ranges were typically 2 orders of magnitude, and analysis times were just a few seconds. Concentration levels of ketosteroids in raw urine relevant to screening for sports doping (approximately 20 ng/mL) can be reached using a simple solid-phase microextraction (SPME) preconcentration step. Reactive DESI provided significant improvements in ionization efficiency of these steroids in raw undiluted urine as compared to conventional DESI; suppression effects due to the sample matrix were minimal and the urine matrix had no deleterious effect on steroid detection limits. Tandem mass spectrometry provided confirmation of analyte identification in this rapid screening process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Advances in Solid Phase Microextraction and Perspective on Future Directions
Reyes-Garcés, N., Gionfriddo, E., Gómez-Ríos, G. A., Alam, M. N., Boyacı, E., Bojko, B., Singh, V., Grandy, J., & Pawliszyn, J. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04502 · Cited by 735
Development, Characterization, and Application of Paper Spray Ionization
Liu, J., Wang, H., Manicke, N. E., Lin, J.-M., Cooks, R. G., & Ouyang, Z. (2010) · Analytical Chemistry · doi:10.1021/ac902854g · Cited by 711
Self-citationMass spectrometry imaging under ambient conditions
Wu, C., Dill, A. L., Eberlin, L. S., Cooks, R. G., & Ifa, D. R. (2013) · Mass Spectrometry Reviews · doi:10.1002/mas.21360 · Cited by 488
Self-citationGirod, M., Moyano, E., Campbell, D. I., & Cooks, R. G. (2011) · Chem. Sci. · doi:10.1039/c0sc00416b · Cited by 419
Self-citationIfa, D. R., Wu, C., Ouyang, Z., & Cooks, R. G. (2010) · The Analyst · doi:10.1039/b925257f · Cited by 384
Self-citation
Metadata
- Authors
- Huang, G., Chen, H., Zhang, X., Cooks, R. G., & Ouyang, Z.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-10-05
- Volume
- 79
- Issue
- 21
- Pages
- 8327-8332
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1968466443
- Cited by
- 201
- References
- 0
- FWCI
- 7.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid Screening of Anabolic Steroids in Urine by Reactive Desorption Electrospray Ionization. https://app.cochat.ai/papers/10.1021/ac0711079
- The paper
- Huang, G., Chen, H., Zhang, X., Cooks, R. G., & Ouyang, Z. (2007). Rapid Screening of Anabolic Steroids in Urine by Reactive Desorption Electrospray Ionization. Analytical Chemistry. https://doi.org/10.1021/ac0711079
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.