Intact Protein Profiling of Chlorobium tepidum by Capillary Isoelectric Focusing, Reversed-Phase Liquid Chromatography, and Mass Spectrometry
The DOI matches its Crossref record.
Abstract
Capillary isoelectric focusing (CIEF) coupled with reversed-phase liquid chromatography (RPLC) and electrospray ionization (ESI) mass spectrometry (MS) is shown to provide a liquid-based alternative to 2D-PAGE for intact protein profiling. This combination exhibits high resolution, sensitivity and throughput for protein profiling based on pI vs MW. The CIEF-RPLC-MS system described here facilitates the use of IEF markers for internal calibration of pI. It also provides a high dynamic range as evidenced by the detection of 100 pg (3 fmol) of a test protein spiked into 1 microg of a complex protein mixture. About 1200 individual proteins/polypeptides were detected from lysates of the green sulfur bacterium Chlorobium tepidum in a single <8 h run. The pI vs MW profile obtained from CIEF-RPLC-MS compares favorably with theoretical data derived from the C. tepidum genome and experimental data obtained from 2D-PAGE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Top Down proteomics: Facts and perspectives
Catherman, A. D., Skinner, O. S., & Kelleher, N. L. (2014) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2014.02.041 · Cited by 507
“Using this platform, 1200 polypeptides/proteins from Chlorobium tepidum were detected over an eight hour separation [69].”
MethodMicrofluidics: Applications for analytical purposes in chemistry and biochemistry
Ohno, K., Tachikawa, K., & Manz, A. (2008) · ELECTROPHORESIS · doi:10.1002/elps.200800121 · Cited by 398
Biodegradation of polyethylene and polystyrene: From microbial deterioration to enzyme discovery
Zhang, Y., Pedersen, J. N., Eser, B. E., & Guo, Z. (2022) · Biotechnology Advances · doi:10.1016/j.biotechadv.2022.107991 · Cited by 369
Zhang, Z., Wu, S., Stenoien, D. L., & Paša-Tolić, L. (2014) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071213-020216 · Cited by 323
Kellie, J. F., Tran, J. C., Lee, J. E., Ahlf, D. R., Thomas, H. M., Ntai, I., Catherman, A. D., Durbin, K. R., Zamdborg, L., Vellaichamy, A., et al. (2010) · Molecular BioSystems · doi:10.1039/c000896f · Cited by 99
Metadata
- Authors
- Zhou, F., Hanson, T. E., & Johnston, M. V.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-08-22
- Volume
- 79
- Issue
- 18
- Pages
- 7145-7153
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2021264755
- Cited by
- 44
- References
- 0
- FWCI
- 2.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intact Protein Profiling of Chlorobium tepidum by Capillary Isoelectric Focusing, Reversed-Phase Liquid Chromatography, and Mass Spectrometry. https://app.cochat.ai/papers/10.1021/ac071147c
- The paper
- Zhou, F., Hanson, T. E., & Johnston, M. V. (2007). Intact Protein Profiling of Chlorobium tepidum by Capillary Isoelectric Focusing, Reversed-Phase Liquid Chromatography, and Mass Spectrometry. Analytical Chemistry. https://doi.org/10.1021/ac071147c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.