The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Loop-Mediated Isothermal Amplification Integrated on Microfluidic Chips for Point-of-Care Quantitative Detection of Pathogens
Abstract
This work shows that loop-mediated isothermal amplification (LAMP) of nucleic acid can be integrated in an eight-channel microfluidic chip for readout either by the naked eye (as a result of the insoluble byproduct pyrophosphate generating during LAMP amplification) or via absorbance measured by an optic sensor; we call this system microLAMP (microLAMP). It is capable of analyzing target nucleic acids quantitatively with high sensitivity and specificity. The assay is straightforward in manipulation. It requires a sample volume of 0.4 microL and is complete within 1 h. The sensitivity of the assay is comparable to standard methods, where 10 fg of DNA sample could be detected under isothermal conditions (63 degrees C). A real time quantitative microLAMP assay using absorbance detection is possible by integration of optical fibers within the chip.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Cited by
Point-of-care diagnostics for infectious diseases: From methods to devices
Wang, C., Liu, M., Wang, Z., Li, S., Deng, Y., & He, N. (2021) · Nano Today · doi:10.1016/j.nantod.2021.101092 · Cited by 622
Becherer, L., Borst, N., Bakheit, M., Frischmann, S., Zengerle, R., & von Stetten, F. (2020) · Analytical Methods · doi:10.1039/c9ay02246e · Cited by 429
Brief review of monitoring methods for loop-mediated isothermal amplification (LAMP)
Zhang, X., Lowe, S. B., & Gooding, J. J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.05.039 · Cited by 368
Micro Total Analysis Systems for Cell Biology and Biochemical Assays
Kovarik, M. L., Gach, P. C., Ornoff, D. M., Wang, Y., Balowski, J., Farrag, L., & Allbritton, N. L. (2012) · Analytical Chemistry · doi:10.1021/ac202611x · Cited by 270
Biomarker detection for disease diagnosis using cost-effective microfluidic platforms
Sanjay, S. T., Fu, G., Dou, M., Xu, F., Liu, R., Qi, H., & Li, X. (2015) · The Analyst · doi:10.1039/c5an00780a · Cited by 267
Metadata
- Authors
- Fang, X., Liu, Y., Kong, J., & Jiang, X.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-03-10
- Volume
- 82
- Issue
- 7
- Pages
- 3002-3006
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2021031313
- Cited by
- 292
- References
- 1
- FWCI
- 15.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Loop-Mediated Isothermal Amplification Integrated on Microfluidic Chips for Point-of-Care Quantitative Detection of Pathogens. https://app.cochat.ai/papers/10.1021/ac1000652
- The paper
- Fang, X., Liu, Y., Kong, J., & Jiang, X. (2010). Loop-Mediated Isothermal Amplification Integrated on Microfluidic Chips for Point-of-Care Quantitative Detection of Pathogens. Analytical Chemistry. https://doi.org/10.1021/ac1000652
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.