One-Dimensional Capillary Liquid Chromatographic Separation Coupled with Tandem Mass Spectrometry Unveils the Escherichia coli Proteome on a Microarray Scale
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We successfully identified the proteome expressed in Escherichia coli (E. coli) cells on a microarray scale using one-dimensional capillary liquid chromatography-tandem mass spectrometry (LC-MS/MS) with a 350 cm long, 100 microm i. d., monolithic silica-C(18) capillary column. E. coli tryptic digest (4 microg) was injected onto the column, and a 41 h gradient was applied with a flow rate of 500 nL/min at less than 20 MPa. In total, 22,196 nonredundant tryptic peptides from 2602 proteins, including 830 membrane proteins, were identified from the E. coli cells (triplicate analysis), in which an equivalent number of genes was detected by transcriptome analysis. Approximately a 5-fold larger peak response on average was obtained in this system, compared with that obtained by conventional capillary LC-MS/MS analysis with a 15 cm long, 3 microm diameter C(18) silica particle-packed column. The higher response suggests that the influence of ionization suppression was drastically reduced by the high-efficiency separation on the long monolithic silica column coupled with the shallow gradient. Because this high-resolution system does not require any additional separation prior to LC-MS/MS, this "one-shot" proteomics approach can simplify the workflow of shotgun proteomics and minimize the sample amount, as well as reduce the total analysis time, despite the use of prolonged shallow gradient elution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A quantitative atlas of mitotic phosphorylation
Dephoure, N., Zhou, C., Villén, J., Beausoleil, S. A., Bakalarski, C. E., Elledge, S. J., & Gygi, S. P. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0805139105 · Cited by 1,608
Comprehensive mass-spectrometry-based proteome quantification of haploid versus diploid yeast
de Godoy, L. M. F., Olsen, J. V., Cox, J., Nielsen, M. L., Hubner, N. C., Fröhlich, F., Walther, T. C., & Mann, M. (2008) · Nature · doi:10.1038/nature07341 · Cited by 873
Cited by
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Hierarchically porous materials: synthesis strategies and structure design
Yang, X.-Y., Chen, L.-H., Li, Y., Rooke, J. C., Sanchez, C., & Su, B.-L. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00829a · Cited by 1,439
Deep and Highly Sensitive Proteome Coverage by LC-MS/MS Without Prefractionation
Thakur, S. S., Geiger, T., Chatterjee, B., Bandilla, P., Fröhlich, F., Cox, J., & Mann, M. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.003699 · Cited by 337
Zhang, Z., Wu, S., Stenoien, D. L., & Paša-Tolić, L. (2014) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071213-020216 · Cited by 323
Doellinger, J., Schneider, A., Hoeller, M., & Lasch, P. (2020) · Molecular & Cellular Proteomics · doi:10.1074/mcp.tir119.001616 · Cited by 246
Ultrasensitive and Fast Bottom‐up Analysis of Femtogram Amounts of Complex Proteome Digests
Sun, L., Zhu, G., Zhao, Y., Yan, X., Mou, S., & Dovichi, N. J. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201308139 · Cited by 212
Generating and navigating proteome maps using mass spectrometry
Ahrens, C. H., Brunner, E., Qeli, E., Basler, K., & Aebersold, R. (2010) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2973 · Cited by 168
Metadata
- Authors
- Iwasaki, M., Miwa, S., Ikegami, T., Tomita, M., Tanaka, N., & Ishihama, Y.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-03-11
- Volume
- 82
- Issue
- 7
- Pages
- 2616-2620
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1969303200
- Cited by
- 131
- References
- 2
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.