The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Efficient Fluorescence Resonance Energy Transfer-Based Ratiometric Fluorescent Cellular Imaging Probe for Zn2+ Using a Rhodamine Spirolactam as a Trigger
Abstract
This letter described the design and synthesis of a novel fluorescein-appended rhodamine spirolactam derivative and its preliminary application as a ratiometric fluorescent cellular imaging probe for Zn(2+). The ratiometric fluorescent signal change of the probe is based on an intramolecular fluorescence resonance energy transfer (FRET) mechanism modulated by a specific metal ion induced ring-opening process of the rhodamine spirolactam (acting as a trigger). In the new developed sensing system, the emission peaks of the two fluorophores are well-resolved, which can avoid the emission spectra overlap problem generally met by spectra-shift type probes and benefits for observation of fluorescence signal change at two different emission wavelengths with high resolution. It also benefits for a large range of emission ratios, thereby a high sensitivity for Zn(2+)detection. Under optimized experimental conditions, the probe exhibits a stable response for Zn(2+) over a concentration range from 2.0 x 10(-7) to 2.0 x 10(-5) M, with a detection limit of 4.0 x 10(-8) M. Most importantly, the novel probe has well solved the problem of serious interferences from other transition metal ions generally met by previously reported typical fluorescent probes for Zn(2+) with the di(2-picolyl)amine moiety as the receptor (in this case, the fluorescence response induced by Cd(2+)is even comparable to that of Zn(2+)) and shows a reversible and fast response toward Zn(2+). All these unique features make it particularly favorable for ratiometric cellular imaging investigations. It has been preliminarily used for ratiometric imaging of Zn(2+) in living cells with satisfying resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Small-Molecule Fluorescent Sensors for Investigating Zinc Metalloneurochemistry
Nolan, E. M., & Lippard, S. J. (2009) · Accounts of Chemical Research · doi:10.1021/ar8001409 · Cited by 620
Cited by
Design Strategies for Water-Soluble Small Molecular Chromogenic and Fluorogenic Probes
Li, X., Gao, X., Shi, W., & Ma, H. (2014) · Chemical Reviews · doi:10.1021/cr300508p · Cited by 1,729
Hybrid Rhodamine Fluorophores in the Visible/NIR Region for Biological Imaging
Wang, L., Du, W., Hu, Z., Uvdal, K., Li, L., & Huang, W. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201901061 · Cited by 348
Yao, J., Zhang, K., Zhu, H., Ma, F., Sun, M., Yu, H., Sun, J., & Wang, S. (2013) · Analytical Chemistry · doi:10.1021/ac401011r · Cited by 286
Metadata
- Authors
- Han, Z.-X., Zhang, X.-B., Li, Z., Gong, Y.-J., Wu, X.-Y., Jin, Z., He, C.-M., Jian, L.-X., Zhang, J., Shen, G.-L., & Yu, R.-Q.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-03-25
- Volume
- 82
- Issue
- 8
- Pages
- 3108-3113
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2056479339
- Cited by
- 245
- References
- 1
- FWCI
- 11.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Efficient Fluorescence Resonance Energy Transfer-Based Ratiometric Fluorescent Cellular Imaging Probe for Zn2+ Using a Rhodamine Spirolactam as a Trigger. https://app.cochat.ai/papers/10.1021/ac100376a
- The paper
- Han, Z.-X., Zhang, X.-B., Li, Z., Gong, Y.-J., Wu, X.-Y., Jin, Z., He, C.-M., Jian, L.-X., Zhang, J., Shen, G.-L., & Yu, R.-Q. (2010). Efficient Fluorescence Resonance Energy Transfer-Based Ratiometric Fluorescent Cellular Imaging Probe for Zn2+ Using a Rhodamine Spirolactam as a Trigger. Analytical Chemistry. https://doi.org/10.1021/ac100376a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.