The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Metering the Capillary-Driven Flow of Fluids in Paper-Based Microfluidic Devices
Abstract
This article describes an exceedingly simple and low-cost method for metering the capillary-driven flow rate of fluids within three-dimensional (3D) microfluidic, paper-based analytical devices (microPADs). Initial prototypes of 3D microPADs control the spatial distribution of fluids within a device, but they provide little control over how quickly (or slowly) fluids move within the device. The methods described in this article provide control over when and how quickly a fluid is distributed into detection zones. These methods are inexpensive (the metering regions are composed of paraffin wax), the devices are easy to fabricate, and they are capable of controlling the flow of fluids to detection zones with precise time delays (e.g., +/-6% of the total wicking time). We anticipate that this type of precise control over fluid distribution rates will be useful particularly for point-of-care assays that require multiple steps (where each step requires that the reagents interact for a defined period of time) or for simultaneously displaying the results of multiple different assays on a single device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Cited by
Microfluidic Paper-Based Analytical Devices: From Design to Applications
Noviana, E., Ozer, T., Carrell, C. S., Link, J. S., McMahon, C., Jang, I., & Henry, C. S. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01335 · Cited by 631
Turning the Page: Advancing Paper-Based Microfluidics for Broad Diagnostic Application
Gong, M. M., & Sinton, D. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00024 · Cited by 573
Integration of paper-based microfluidic devices with commercial electrochemical readers
Nie, Z., Deiss, F., Liu, X., Akbulut, O., & Whitesides, G. M. (2010) · Lab on a Chip · doi:10.1039/c0lc00237b · Cited by 481
Micro Total Analysis Systems for Cell Biology and Biochemical Assays
Kovarik, M. L., Gach, P. C., Ornoff, D. M., Wang, Y., Balowski, J., Farrag, L., & Allbritton, N. L. (2012) · Analytical Chemistry · doi:10.1021/ac202611x · Cited by 270
Acoustically-driven thread-based tuneable gradient generators
Ramesan, S., Rezk, A. R., Cheng, K. W., Chan, P. P. Y., & Yeo, L. Y. (2016) · Lab on a Chip · doi:10.1039/c5lc00937e · Cited by 33
Metadata
- Authors
- Noh, H., & Phillips, S. T.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-04-22
- Volume
- 82
- Issue
- 10
- Pages
- 4181-4187
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1970019073
- Cited by
- 203
- References
- 1
- FWCI
- 9.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.