We have developed a rapid and homogeneous method for the highly selective detection of Hg(2+) and Ag(+) using Tween 20-modified gold nanoparticles (AuNPs). Citrate ions were found to still be adsorbed on the Au surface when citrate-capped AuNPs were modified with Tween 20, which stabilizes the citrate-capped AuNPs against conditions of high ionic strength. When citrate ions had reduced Hg(2+) and Ag(+) to form Hg-Au alloys and Ag on the surface of the AuNPs, Tween 20 was removed from the NP surface. As a result, the AuNPs were unstable under a high-ionic-strength solution, resulting in NP aggregation. The formation of Hg-Au alloys or Ag on the surface of the AuNPs was demonstrated by means of inductively coupled plasma mass spectroscopy and energy-dispersive X-ray spectroscopy. Tween 20-AuNPs could selectively detect Hg(2+) and Ag(+) at concentrations as low as 0.1 and 0.1 microM in the presence of NaCl and EDTA, respectively. Moreover, the probe enables the analysis of AgNPs with a minimum detectable concentration that corresponds to 1 pM. This probe was successfully applied to detect Hg(2+) in drinking water and seawater, Ag(+) in drinking water, and AgNPs in drinking water.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 46
- Campbell L., 2003, J. Toxicol. Environ. Health, Part B, 6, 325, 10.1080/10937400306474 · DOI · Paper page
- Wood C. M., 2004, Aquat. Toxicol., 70, 137, 10.1016/j.aquatox.2004.08.002 · doi:10.1016/j.aquatox.2004.08.002
- Boening D. W., 2000, Chemosphere., 40, 1335, 10.1016/S0045-6535(99)00283-0 · DOI · Paper page
- Ratte H. T., 1999, Environ. Toxicol. Chem., 18, 89, 10.1002/etc.5620180112 · DOI · Paper page
- Holmes P., 2009, Sci. Total Environ., 408, 171, 10.1016/j.scitotenv.2009.09.043 · DOI · Paper page
- Karunasagar D., 1998, J. Anal. At. Spectrom., 13, 679, 10.1039/A802132E · doi:10.1039/a802132e
- Barriada J. L., 2007, TrAC, Trends Anal. Chem., 26, 809, 10.1016/j.trac.2007.06.004 · DOI · Paper page
- Li Y., 2006, J. Anal. At. Spectrom., 21, 94, 10.1039/B511367A · doi:10.1039/b511367a
- Chamsaz M., 2008, Anal. Sci., 24, 799, 10.2116/analsci.24.799 · DOI
- Kim H. J., 1998, Electroanalysis, 10, 303, 10.1002/(SICI)1521-4109(199804)10:5<303::AID-ELAN303>3.0.CO;2-A · doi:10.1002/(sici)1521-4109(199804)10:5<303::aid-elan303>3.0.co;2-a
- Mikelova R., 2007, Bioelectrochemistry, 70, 508, 10.1016/j.bioelechem.2006.12.001 · DOI
- Chatterjee A., 2009, J. Am. Chem. Soc., 131, 2040, 10.1021/ja807230c · DOI · Paper page
- Zhan X. Q., 2008, Chem. Commun., 1859, 10.1039/b719473k · doi:10.1039/b719473k
- Lin Y.-H., 2009, Chem. Commun., 6619, 10.1039/b915990h · DOI
- Wang J., 2008, Chem. Commun., 4759, 10.1039/b806885b · doi:10.1039/b806885b
- Li T., 2009, Chemistry, 15, 3347, 10.1002/chem.200900056 · DOI · Paper page
- Hollenstein M., 2008, Angew. Chem., Int. Ed., 47, 4346, 10.1002/anie.200800960 · DOI · Paper page
- Koneswaran M., 2009, Sens. Actuators, B, 139, 91, 10.1016/j.snb.2008.09.011 · DOI
- Chen J.-L., 2005, Anal. Chim. Acta, 546, 147, 10.1016/j.aca.2005.05.006 · DOI · Paper page
- Huang C.-C., 2006, Anal. Chem., 78, 8332, 10.1021/ac061487i · DOI · Paper page
- Yu C.-J., 2008, Langmuir, 24, 12717, 10.1021/la802105b · doi:10.1021/la802105b
- Darbha G. K., 2008, J. Am. Chem. Soc., 130, 8038, 10.1021/ja801412b · DOI · Paper page
- Tanaka Y., 2007, J. Am. Chem. Soc., 129, 244, 10.1021/ja065552h · DOI · Paper page
- Lee J.-S., 2007, Angew. Chem., Int. Ed., 46, 4093, 10.1002/anie.200700269 · DOI · Paper page
- Xue X., 2008, J. Am. Chem. Soc., 130, 3244, 10.1021/ja076716c · DOI · Paper page
- Yu C.-J., 2009, Biosens. Bioelectron., 25, 204, 10.1016/j.bios.2009.06.038 · doi:10.1016/j.bios.2009.06.038
- Li D., 2008, Angew. Chem., Int. Ed., 47, 3927, 10.1002/anie.200705991 · DOI · Paper page
- Liu C.-W., 2008, Chem. Commun., 2242, 10.1039/b719856f · doi:10.1039/b719856f
- Rex M., 2006, Anal. Chem., 78, 445, 10.1021/ac051166r · doi:10.1021/ac051166r
- Leopold K., 2009, J. Anal. Chem., 81, 3421, 10.1021/ac802685s · DOI
- Lisha K. P., 2009, Gold Bull., 42, 144, 10.1007/BF03214924 · DOI
- Barrosse-Antle L. E., 2007, New J. Chem., 31, 2071, 10.1039/b706810g · doi:10.1039/b706810g
- Li B., 2009, Anal. Chim. Acta, 644, 78, 10.1016/j.aca.2009.04.022 · DOI
- Huang C.-C., 2009, Analyst, 134, 1699, 10.1039/b900028c · doi:10.1039/b900028c
- Wei H., 2008, Anal. Chem., 80, 7051, 10.1021/ac801144t · DOI · Paper page
- Su C.-L., 2007, Anal. Chem., 79, 1626, 10.1021/ac061747w · doi:10.1021/ac061747w
- Wu H.-P., 2009, J. Am. Soc. Mass Spectrom., 20, 875, 10.1016/j.jasms.2009.01.002 · doi:10.1016/j.jasms.2009.01.002
- Xie W., 2009, Chem. Commun., 5263, 10.1039/b905998a · doi:10.1039/b905998a
- Xia H., 2009, Langmuir
- Shen C.-C., 2009, J. Chromatogr., A, 1216, 288, 10.1016/j.chroma.2008.11.044 · DOI
- Morris T., 2002, Langmuir, 18, 7261, 10.1021/la020229n · doi:10.1021/la020229n
- Anandan S., 2008, J. Phys. Chem. C, 112, 15102, 10.1021/jp806960r · DOI · Paper page
- Guerrini L., 2010, J. Raman Spectrosc., 41, 508, 10.1002/jrs.2469 · doi:10.1002/jrs.2469
- Huang C.-C., 2008, Anal. Chem., 80, 6345, 10.1021/ac8006973 · DOI
- Lubick N., 2008, Environ. Sci. Technol., 42, 8617, 10.1021/es8026314 · DOI · Paper page
- Benn T. M., 2008, Environ. Sci. Technol., 42, 4133, 10.1021/es7032718 · DOI · Paper page
Cited by
Colorimetric sensors for rapid detection of various analytes
Piriya V.S, A., Joseph, P., Daniel S.C.G., K., Lakshmanan, S., Kinoshita, T., & Muthusamy, S. (2017) · Materials Science and Engineering: C · doi:10.1016/j.msec.2017.05.018 · Cited by 441
Fluorescent and colorimetric sensors for environmental mercury detection
Chen, G., Guo, Z., Zeng, G., & Tang, L. (2015) · The Analyst · doi:10.1039/c5an00389j · Cited by 335
Plasmonic colorimetric and SERS sensors for environmental analysis
Wei, H., Hossein Abtahi, S. M., & Vikesland, P. J. (2015) · Environmental Science: Nano · doi:10.1039/c4en00211c · Cited by 285
Kang, T., Yoo, S. M., Kang, M., Lee, H., Kim, H., Lee, S. Y., & Kim, B. (2012) · Lab on a Chip · doi:10.1039/c2lc40185a · Cited by 68
Metadata
- Authors
- Lin, C.-Y., Yu, C.-J., Lin, Y.-H., & Tseng, W.-L.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-07-16
- Volume
- 82
- Issue
- 16
- Pages
- 6830-6837
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2077021162
- Cited by
- 410
- References
- 0
- FWCI
- 13.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.