The DOI matches its Crossref record.
Automated Broadband Phase Correction of Fourier Transform Ion Cyclotron Resonance Mass Spectra
Abstract
It has been known for 35 years that phase correction of FTICR data can in principle produce an absorption-mode spectrum with mass resolving power as much as a factor of 2 higher than conventional magnitude-mode display, an improvement otherwise requiring a (much more expensive) increase in magnetic field strength. However, temporally dispersed excitation followed by time-delayed detection results in steep quadratic variation of signal phase with frequency. Here, we present a robust, rapid, automated method to enable accurate broadband phase correction for all peaks in the mass spectrum. Low-pass digital filtering effectively eliminates the accompanying baseline roll. Experimental FTICR absorption-mode mass spectra exhibit at least 40% higher resolving power (and thus an increased number of resolved peaks) as well as higher mass accuracy relative to magnitude mode spectra, for more complete and more reliable elemental composition assignments for mixtures as complex as petroleum.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zubarev, R. A., & Makarov, A. (2013) · Analytical Chemistry · doi:10.1021/ac4001223 · Cited by 658
21 Tesla FT-ICR Mass Spectrometer for Ultrahigh-Resolution Analysis of Complex Organic Mixtures
Smith, D. F., Podgorski, D. C., Rodgers, R. P., Blakney, G. T., & Hendrickson, C. L. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04159 · Cited by 348
Self-citationZhang, Z., Wu, S., Stenoien, D. L., & Paša-Tolić, L. (2014) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071213-020216 · Cited by 323
Hendrickson, C. L., Quinn, J. P., Kaiser, N. K., Smith, D. F., Blakney, G. T., Chen, T., Marshall, A. G., Weisbrod, C. R., & Beu, S. C. (2015) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-015-1182-2 · Cited by 278
Self-citationHigh Resolution Mass Spectrometry
Xian, F., Hendrickson, C. L., & Marshall, A. G. (2012) · Analytical Chemistry · doi:10.1021/ac203191t · Cited by 281
Self-citation
Metadata
- Authors
- Xian, F., Hendrickson, C. L., Blakney, G. T., Beu, S. C., & Marshall, A. G.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-10-14
- Volume
- 82
- Issue
- 21
- Pages
- 8807-8812
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2317768851
- Cited by
- 189
- References
- 0
- FWCI
- 6.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated Broadband Phase Correction of Fourier Transform Ion Cyclotron Resonance Mass Spectra. https://app.cochat.ai/papers/10.1021/ac101091w
- The paper
- Xian, F., Hendrickson, C. L., Blakney, G. T., Beu, S. C., & Marshall, A. G. (2010). Automated Broadband Phase Correction of Fourier Transform Ion Cyclotron Resonance Mass Spectra. Analytical Chemistry. https://doi.org/10.1021/ac101091w
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.