The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Cleavable Cross-Linker for Protein Structure Analysis: Reliable Identification of Cross-Linking Products by Tandem MS
Abstract
Chemical cross-linking combined with a subsequent enzymatic cleavage of the created cross-linked complex and a mass spectrometric analysis of the resulting cross-linked peptide mixture presents an alternative approach to high-resolution analysis, such as NMR spectroscopy or X-ray crystallography, to obtain low-resolution protein structures and to gain insight into protein interfaces. Here, we describe a novel urea-based cross-linker, which allows distinguishing different cross-linking products by collision-induced dissociation (CID) tandem MS experiments based on characteristic product ions and constant neutral losses. The novel cross-linker is part of our ongoing efforts in developing collision-induced dissociative reagents that allow an efficient analysis of cross-linked proteins and protein complexes. Our innovative analytical concept is exemplified for the Munc13-1 peptide and the recombinantly expressed ligand binding domain of the peroxisome proliferator-activated receptor alpha, for which cross-linking reaction mixtures were analyzed both by offline nano-HPLC/MALDI-TOF/TOF mass spectrometry and by online nano-HPLC/nano-ESI-LTQ-orbitrap mass spectrometry. The characteristic fragment ion patterns of the novel cross-linker greatly simplify the identification of different cross-linked species, namely, modified peptides as well as intrapeptide and interpeptide cross-links, from complex mixtures and drastically reduce the potential of identifying false-positive cross-links. Our novel urea-based CID cleavable cross-linker is expected to be highly advantageous for analyzing protein 3D structures and protein-protein complexes in an automated manner.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Cited by
Liu, F., Lössl, P., Scheltema, R., Viner, R., & Heck, A. J. R. (2017) · Nature Communications · doi:10.1038/ncomms15473 · Cited by 284
The diverse and expanding role of mass spectrometry in structural and molecular biology
Lössl, P., van de Waterbeemd, M., & Heck, A. J. (2016) · The EMBO Journal · doi:10.15252/embj.201694818 · Cited by 222
Yugandhar, K., Gupta, S., & Yu, H. (2019) · Computational and Structural Biotechnology Journal · doi:10.1016/j.csbj.2019.05.007 · Cited by 51
“Later, the inception of MS-cleavable cross-linkers such as disuccinimidyl sulfoxide (DSSO) [39], disuccinimidyl dibutyric urea (DSBU) [40,41] and 1,1 ′ - carbonyldiimidazole (CDI) [42], which generate a fragment ion signature that provides additional information for database search and reduce the number of iterations…”
BackgroundAltmannova, V., Firlej, M., Müller, F., Janning, P., Rauleder, R., Rousova, D., Schäffler, A., Bange, T., & Weir, J. R. (2023) · Nucleic Acids Research · doi:10.1093/nar/gkad175 · Cited by 15
Birklbauer, M. J., Müller, F., Geetha, S. S., Matzinger, M., Mechtler, K., & Dorfer, V. (2024) · Communications Chemistry · doi:10.1038/s42004-024-01386-x · Cited by 11
Metadata
- Authors
- Müller, M. Q., Dreiocker, F., Ihling, C. H., Schäfer, M., & Sinz, A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-07-22
- Volume
- 82
- Issue
- 16
- Pages
- 6958-6968
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2055442886
- Cited by
- 231
- References
- 1
- FWCI
- 3.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cleavable Cross-Linker for Protein Structure Analysis: Reliable Identification of Cross-Linking Products by Tandem MS. https://app.cochat.ai/papers/10.1021/ac101241t
- The paper
- Müller, M. Q., Dreiocker, F., Ihling, C. H., Schäfer, M., & Sinz, A. (2010). Cleavable Cross-Linker for Protein Structure Analysis: Reliable Identification of Cross-Linking Products by Tandem MS. Analytical Chemistry. https://doi.org/10.1021/ac101241t
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.