The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Identification of Biological Tissues by Rapid Evaporative Ionization Mass Spectrometry
Abstract
The newly developed rapid evaporative ionization mass spectrometry (REIMS) provides the possibility of in vivo, in situ mass spectrometric tissue analysis. The experimental setup for REIMS is characterized in detail for the first time, and the description and testing of an equipment capable of in vivo analysis is presented. The spectra obtained by various standard surgical equipments were compared and found highly specific to the histological type of the tissues. The tissue analysis is based on their different phospholipid distribution; the identification algorithm uses a combination of principal component analysis (PCA) and linear discriminant analysis (LDA). The characterized method was proven to be sensitive for any perturbation such as age or diet in rats, but it was still perfectly suitable for tissue identification. Tissue identification accuracy higher than 97% was achieved with the PCA/LDA algorithm using a spectral database collected from various tissue species. In vivo, ex vivo, and post mortem REIMS studies were performed, and the method was found to be applicable for histological tissue analysis during surgical interventions, endoscopy, or after surgery in pathology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Han, X., & Gross, R. W. (2003) · Journal of Lipid Research · doi:10.1194/jlr.r300004-jlr200 · Cited by 914
Cited by
Intraoperative Tissue Identification Using Rapid Evaporative Ionization Mass Spectrometry
Balog, J., Sasi-Szabó, L., Kinross, J., Lewis, M. R., Muirhead, L. J., Veselkov, K., Mirnezami, R., Dezső, B., Damjanovich, L., Darzi, A., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3005623 · Cited by 608
Self-citationAmbient Sampling/Ionization Mass Spectrometry: Applications and Current Trends
Harris, G. A., Galhena, A. S., & Fernández, F. M. (2011) · Analytical Chemistry · doi:10.1021/ac200918u · Cited by 527
Mass spectrometry imaging under ambient conditions
Wu, C., Dill, A. L., Eberlin, L. S., Cooks, R. G., & Ifa, D. R. (2013) · Mass Spectrometry Reviews · doi:10.1002/mas.21360 · Cited by 488
Recent developments in liquid chromatography–mass spectrometry and related techniques
Holčapek, M., Jirásko, R., & Lísa, M. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.08.072 · Cited by 330
A Review of Applications of Metabolomics in Cancer
Beger, R. (2013) · Metabolites · doi:10.3390/metabo3030552 · Cited by 288
Metadata
- Authors
- Balog, J., Szaniszlo, T., Schaefer, K.-C., Denes, J., Lopata, A., Godorhazy, L., Szalay, D., Balogh, L., Sasi-Szabo, L., Toth, M., & Takats, Z.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-08-03
- Volume
- 82
- Issue
- 17
- Pages
- 7343-7350
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2044378040
- Cited by
- 231
- References
- 1
- FWCI
- 4.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.