The DOI matches its Crossref record.
Ultrasensitive Sensing of Hg2+ and CH3Hg+ Based on the Fluorescence Quenching of Lysozyme Type VI-Stabilized Gold Nanoclusters
Abstract
This study presents a one-step approach to prepare lysozyme type VI-stabilized gold nanoclusters (Lys VI-AuNCs) for the ultrasensitive detection of Hg(2+) and CH(3)Hg(+) based on fluorescence quenching. The optical properties and size of Lys VI-AuNCs are highly dependent on the concentration of Lys VI, which acts as both a reducing and a stabilizing agent. With an increase in the concentration of Lys VI, we observed a systematic blue shift in the fluorescence maxima, an increase in the quantum yields, and a reduction in the particle size. When using 25 mg/mL Lys VI as a reducing agent, the formed Lys VI-AuNCs (denoted as Au-631) were found to be highly stable in a high-concentration glutathione or NaCl. Additionally, the Au-631 were capable of sensing Hg(2+) and CH(3)Hg(+) through the interaction between Hg(2+)/CH(3)Hg(+) and Au(+) on the Au surface; the limits of detection (LODs) for Hg(2+) and CH(3)Hg(+) were 3 pM and 4 nM, respectively. The selectivity of this probe is more than 500-fold for Hg(2+) over any metal ions. As compared to bovine serum albumin-stabilized AuNCs, Au-631 provided an approximately 330-fold improvement in the detection of Hg(2+). To the best of our knowledge, Au-631 not only provide the first example for detecting CH(3)Hg(+) but also have the lowest LOD value for Hg(2+) when compared to other AuNC-based Hg(2+) sensors. Importantly, this probe was successfully applied to the determination of Hg(2+) and CH(3)Hg(+) in seawater.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Applications of nanotechnology in water and wastewater treatment
Qu, X., Alvarez, P. J. J., & Li, Q. (2013) · Water Research · doi:10.1016/j.watres.2012.09.058 · Cited by 2,444
Lu, W., Qin, X., Liu, S., Chang, G., Zhang, Y., Luo, Y., Asiri, A. M., Al-Youbi, A. O., & Sun, X. (2012) · Analytical Chemistry · doi:10.1021/ac3007939 · Cited by 1,163
Gold Nanomaterials at Work in Biomedicine
Yang, X., Yang, M., Pang, B., Vara, M., & Xia, Y. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00193 · Cited by 1,162
Sub-nanometre sized metal clusters: from synthetic challenges to the unique property discoveries
Lu, Y., & Chen, W. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15325d · Cited by 1,152
Luminescent Noble Metal Nanoclusters as an Emerging Optical Probe for Sensor Development
Yuan, X., Luo, Z., Yu, Y., Yao, Q., & Xie, J. (2013) · Chemistry – An Asian Journal · doi:10.1002/asia.201201236 · Cited by 328
Metadata
- Authors
- Lin, Y.-H., & Tseng, W.-L.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-10-18
- Volume
- 82
- Issue
- 22
- Pages
- 9194-9200
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2043248104
- Cited by
- 336
- References
- 0
- FWCI
- 13.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasensitive Sensing of Hg2+ and CH3Hg+ Based on the Fluorescence Quenching of Lysozyme Type VI-Stabilized Gold Nanoclusters. https://app.cochat.ai/papers/10.1021/ac101427y
- The paper
- Lin, Y.-H., & Tseng, W.-L. (2010). Ultrasensitive Sensing of Hg2+ and CH3Hg+ Based on the Fluorescence Quenching of Lysozyme Type VI-Stabilized Gold Nanoclusters. Analytical Chemistry. https://doi.org/10.1021/ac101427y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.