In this paper, we propose a microfluidic device that is capable of generating a concentration gradient followed by parallel droplet formation within channels with a simple T-junction geometry. Linear concentration gradient profiles can be obtained based on fluid diffusion under laminar flow. Optimized conditions for generating a linear concentration gradient and parallel droplet formation were investigated using fluorescent dye. The concentration gradient profile under diffusive mixing was dominated by the flow rate at sample inlets, while parallel droplet formation was affected by the channel geometry at both the inlet and outlet. The microfluidic device was experimentally characterized using optimal layout and operating conditions selected through a design process. Furthermore, in situ enzyme kinetic measurements of the β-galactosidase-catalyzed hydrolysis of resorufin-β-d-galactopyranoside were performed to demonstrate the application potential of our simple, time-effective, and low sample volume microfluidic device. We expect that, in addition to enzyme kinetics, drug screening and clinical diagnostic tests can be rapidly and accurately performed using this droplet-based microfluidic system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Millisecond Kinetics on a Microfluidic Chip Using Nanoliters of Reagents
Song, H., & Ismagilov, R. F. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0354566 · Cited by 693
A systems approach to measuring the binding energy landscapes of transcription factors.
Maerkl, S. J., & Quake, S. R. (2007) · Science · doi:10.1126/science.1131007 · Cited by 584
Cited by
Analytical detection techniques for droplet microfluidics—A review
Zhu, Y., & Fang, Q. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.04.064 · Cited by 365
Concentration gradient generation methods based on microfluidic systems
Wang, X., Liu, Z., & Pang, Y. (2017) · RSC Advances · doi:10.1039/c7ra04494a · Cited by 219
Sun, M., & Vanapalli, S. A. (2013) · Analytical Chemistry · doi:10.1021/ac303526y · Cited by 26
Neun, S., van Vliet, L., Hollfelder, F., & Gielen, F. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c03164 · Cited by 20
Metadata
- Authors
- Bui, M.-P. N., Li, C. A., Han, K. N., Choo, J., Lee, E. K., & Seong, G. H.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-01-31
- Volume
- 83
- Issue
- 5
- Pages
- 1603-1608
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2321519616
- Cited by
- 84
- References
- 2
- FWCI
- 4.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enzyme Kinetic Measurements Using a Droplet-Based Microfluidic System with a Concentration Gradient. https://app.cochat.ai/papers/10.1021/ac102472a
- The paper
- Bui, M.-P. N., Li, C. A., Han, K. N., Choo, J., Lee, E. K., & Seong, G. H. (2011). Enzyme Kinetic Measurements Using a Droplet-Based Microfluidic System with a Concentration Gradient. Analytical Chemistry. https://doi.org/10.1021/ac102472a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.