The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Significance of Antibody Orientation Unraveled: Well-Oriented Antibodies Recorded High Binding Affinity
Abstract
To investigate the effect of antibody orientation on its immunological activities, we developed a novel and versatile platform consisting of a well-defined phospholipid polymer surface on which staphylococcal protein A (SpA) was site-selectively immobilized. The application of a biocompatible phospholipid-based platform ensured minimal denaturation of immobilized antibodies, and the site-selective immobilization of SpA clarified the effect of antibody orientation on immunological activities. The phospholipid polymer platform was prepared on silicon substrates using the surface-initiated atom transfer radical polymerization (SI-ATRP) technique. An enzymatic reaction was performed for orientation-selective coupling of SpA molecules to the polymer brush surface. Orientation-controlled antibodies were achieved using enzymatic reactions, and these antibodies captured 1.8 ± 0.1 antigens on average, implying that at least 80% of immobilized antibodies reacted with two antigens. Theoretical multivalent binding analysis further revealed that orientation-controlled antibodies had antigen-antibody reaction equilibrium dissociation constants (K(d)) as low as 8.6 × 10(-10) mol/L, whereas randomly oriented and partially oriented antibodies showed K(d) values of 2.0 × 10(-7) and 1.2 × 10(-7) mol/L, respectively. Strict control of antibody orientation not only formed an approximately 100-fold stronger antigen-antibody complex than the controls but also sustained the native antibody K(d) (10(-10)-10(-9) mol/L). These findings support the significance of antibody orientation because controlling the orientation resulted in high reactivity and theoretical binding capacity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The physiological structure of human C-reactive protein and its complex with phosphocholine
Thompson, D., Pepys, M. B., & Wood, S. P. (1999) · Structure · doi:10.1016/s0969-2126(99)80023-9 · Cited by 818
Cited by
Zoppe, J. O., Ataman, N. C., Mocny, P., Wang, J., Moraes, J., & Klok, H.-A. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00314 · Cited by 1,046
Antibody orientation on biosensor surfaces: a minireview
Trilling, A. K., Beekwilder, J., & Zuilhof, H. (2013) · The Analyst · doi:10.1039/c2an36787d · Cited by 466
Synthesis, Assembly, and Applications of Hybrid Nanostructures for Biosensing
Zhang, S., Geryak, R., Geldmeier, J., Kim, S., & Tsukruk, V. V. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00088 · Cited by 340
Leng, Y., Sun, K., Chen, X., & Li, W. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00382a · Cited by 258
Synthetic Ligand-Coated Magnetic Nanoparticles for Microfluidic Bacterial Separation from Blood
Lee, J.-J., Jeong, K. J., Hashimoto, M., Kwon, A. H., Rwei, A., Shankarappa, S. A., Tsui, J. H., & Kohane, D. S. (2014) · Nano Letters · doi:10.1021/nl3047305 · Cited by 258
Metadata
- Authors
- Tajima, N., Takai, M., & Ishihara, K.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-02-21
- Volume
- 83
- Issue
- 6
- Pages
- 1969-1976
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2010305352
- Cited by
- 211
- References
- 1
- FWCI
- 5.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.