The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Antibody orientation on biosensor surfaces: a minireview
Open accessAbstract
Detection elements play a key role in analyte recognition in biosensors. Therefore, detection elements with high analyte specificity and binding strength are required. While antibodies (Abs) have been increasingly used as detection elements in biosensors, a key challenge remains - the immobilization on the biosensor surface. This minireview highlights recent approaches to immobilize and study Abs on surfaces. We first introduce Ab species used as detection elements, and discuss techniques recently used to elucidate Ab orientation by determination of layer thickness or surface topology. Then, several immobilization methods will be presented: non-covalent and covalent surface attachment, yielding oriented or random coupled Abs. Finally, protein modification methods applicable for oriented Ab immobilization are reviewed with an eye to future application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Enzyme-linked immunosorbent assay (ELISA) quantitative assay of immunoglobulin G
Engvall, E., & Perlmann, P. (1971) · Immunochemistry · doi:10.1016/0019-2791(71)90454-x · Cited by 3,777
Naturally occurring antibodies devoid of light chains
Hamers-Casterman, C., Atarhouch, T., Muyldermans, S., Robinson, G., Hammers, C., Songa, E. B., Bendahman, N., & Hammers, R. (1993) · Nature · doi:10.1038/363446a0 · Cited by 3,241
Cell Surface Engineering by a Modified Staudinger Reaction
Saxon, E., & Bertozzi, C. R. (2000) · Science · doi:10.1126/science.287.5460.2007 · Cited by 2,460
Cu-free click cycloaddition reactions in chemical biology
Jewett, J. C., & Bertozzi, C. R. (2010) · Chemical Society Reviews · doi:10.1039/b901970g · Cited by 1,684
Stereoselective Organic Reactions in Water
Lindström, U. M. (2002) · Chemical Reviews · doi:10.1021/cr010122p · Cited by 1,642
Expressed protein ligation: A general method for protein engineering
Muir, T. W., Sondhi, D., & Cole, P. A. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.12.6705 · Cited by 1,189
Kiick, K. L., Saxon, E., Tirrell, D. A., & Bertozzi, C. R. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.012583299 · Cited by 910
Greenberg, A. S., Avila, D., Hughes, M., Hughes, A., McKinney, E. C., & Flajnik, M. F. (1995) · Nature · doi:10.1038/374168a0 · Cited by 775
Addition of p-Azido-l-phenylalanine to the Genetic Code of Escherichia coli
Chin, J. W., Santoro, S. W., Martin, A. B., King, D. S., Wang, L., & Schultz, P. G. (2002) · Journal of the American Chemical Society · doi:10.1021/ja027007w · Cited by 721
Hernandez, K., & Fernandez-Lafuente, R. (2011) · Enzyme and Microbial Technology · doi:10.1016/j.enzmictec.2010.10.003 · Cited by 614
Cited by
Ultrasensitive and Highly Specific Lateral Flow Assays for Point-of-Care Diagnosis
Liu, Y., Zhan, L., Qin, Z., Sackrison, J., & Bischof, J. C. (2021) · ACS Nano · doi:10.1021/acsnano.0c10035 · Cited by 626
Metadata
- Authors
- Trilling, A. K., Beekwilder, J., & Zuilhof, H.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 138
- Issue
- 6
- Pages
- 1619
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2056066120
- Cited by
- 466
- References
- 36
- FWCI
- 13.72
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Antibody orientation on biosensor surfaces: a minireview. https://app.cochat.ai/papers/10.1039/c2an36787d
- The paper
- Trilling, A. K., Beekwilder, J., & Zuilhof, H. (2013). Antibody orientation on biosensor surfaces: a minireview. The Analyst. https://doi.org/10.1039/c2an36787d
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.