On-Chip Electro Membrane Extraction with Online Ultraviolet and Mass Spectrometric Detection
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Electro membrane extraction was demonstrated in a microfluidic device. The device was composed of a 25 μm thick porous polypropylene membrane bonded between two poly(methyl methacrylate) (PMMA) substrates, each having 50 μm deep channel structures facing the membrane. The supported liquid membrane (SLM) consisted of 2-nitrophenyl octyl ether (NPOE) immobilized in the pores of the membrane. The driving force for the extraction was a 15 V direct current (DC) electrical potential applied across the SLM. Samples containing the basic drugs pethidine, nortriptyline, methadone, haloperidol, loperamide, and amitriptyline were used to characterize the system. Extraction recoveries were typically in the range of 65-86% for the different analytes when the device was operated with a sample flow of 2.0 μL/min and an acceptor flow of 1.0 μL/min. With the sample flow at 9.0 μL/min and the acceptor flow at 0.0 μL/min, enrichment factors exceeding 75 were obtained during 12 min of operation from a total sample volume of only 108 μL. The on-chip electro membrane system was coupled online to electrospray ionization mass spectrometry and used to monitor online and real-time metabolism of amitriptyline by rat liver microsomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Cited by
Green aspects, developments and perspectives of liquid phase microextraction techniques
Spietelun, A., Marcinkowski, Ł., de la Guardia, M., & Namieśnik, J. (2014) · Talanta · doi:10.1016/j.talanta.2013.10.050 · Cited by 333
Liquid-phase microextraction – The different principles and configurations
Yamini, Y., Rezazadeh, M., & Seidi, S. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.06.010 · Cited by 309
Recent advances and trends in miniaturized sample preparation techniques
Soares da Silva Burato, J., Vargas Medina, D. A., de Toffoli, A. L., Vasconcelos Soares Maciel, E., & Mauro Lanças, F. (2020) · Journal of Separation Science · doi:10.1002/jssc.201900776 · Cited by 254
Greening Sample Preparation: New Solvents, New Sorbents
Ramos, L. (2020) · Challenges in Green Analytical Chemistry · doi:10.1039/9781788016148-00114 · Cited by 6
Metadata
- Authors
- Petersen, N. J., Foss, S. T., Jensen, H., Hansen, S. H., Skonberg, C., Snakenborg, D., Kutter, J. P., & Pedersen-Bjergaard, S.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-12-10
- Volume
- 83
- Issue
- 1
- Pages
- 44-51
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2074927427
- Cited by
- 106
- References
- 1
- FWCI
- 8.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.