Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 172

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Rapid Prototyping of Arrayed Microfluidic Systems in Polystyrene for Cell-Based Assays

Open access
Young, Edmond W. K., Berthier, Erwin, Guckenberger, David J., Sackmann, Eric, Lamers, Casey, Meyvantsson, Ivar, Huttenlocher, Anna, Beebe, David J.·2011·Analytical Chemistry

Abstract

Microfluidic cell-based systems have enabled the study of cellular phenomena with improved spatiotemporal control of the microenvironment and at increased throughput. While poly(dimethylsiloxane) (PDMS) has emerged as the most popular material in microfluidics research, it has specific limitations that prevent microfluidic platforms from achieving their full potential. We present here a complete process, ranging from mold design to embossing and bonding, that describes the fabrication of polystyrene (PS) microfluidic devices with similar cost and time expenditures as PDMS-based devices. Emphasis was placed on creating methods that can compete with PDMS fabrication methods in terms of robustness, complexity, and time requirements. To achieve this goal, several improvements were made to remove critical bottlenecks in existing PS embossing methods. First, traditional lithographic techniques were adapted to fabricate bulk epoxy molds capable of resisting high temperatures and pressures. Second, a method was developed to emboss through-holes in a PS layer, enabling creation of large arrays of independent microfluidic systems on a single device without need to manually create access ports. Third, thermal bonding of PS layers was optimized in order to achieve quality bonding over large arrays of microsystems. The choice of materials and methods was validated for biological function in two different cell-based applications to demonstrate the versatility of our streamlined fabrication process.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac102897h

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 172

Metadata

Authors
Young, E. W. K., Berthier, E., Guckenberger, D. J., Sackmann, E., Lamers, C., Meyvantsson, I., Huttenlocher, A., & Beebe, D. J.
Venue
Analytical Chemistry
Published
2011-01-24
Volume
83
Issue
4
Pages
1408-1417
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2008828824
Cited by
172
References
4
FWCI
9.12
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Rapid Prototyping of Arrayed Microfluidic Systems in Polystyrene for Cell-Based Assays. https://app.cochat.ai/papers/10.1021/ac102897h
The paper
Young, E. W. K., Berthier, E., Guckenberger, D. J., Sackmann, E., Lamers, C., Meyvantsson, I., Huttenlocher, A., & Beebe, D. J. (2011). Rapid Prototyping of Arrayed Microfluidic Systems in Polystyrene for Cell-Based Assays. Analytical Chemistry. https://doi.org/10.1021/ac102897h

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.