Improved LC−MS Method for the Determination of Fatty Acids in Red Blood Cells by LC−Orbitrap MS
Open accessThe DOI matches its Crossref record.
Abstract
We report a new method for fast and sensitive analyses of biologically relevant fatty acids (FAs) in red blood cells (RBC) by liquid chromatography mass spectrometry (LC-MS). A new chemical derivatization approach was developed forming picolylamides from FAs in a quantitative reaction. Fourteen derivatized FA standards, including saturated and unsaturated FAs from C14 to C22, were efficiently separated within 15 min. In addition, the use of a recently introduced benchtop orbitrap mass spectrometer under positive electrospray ionization (ESI) full scan mode showed a 2-10-fold improvement in sensitivity compared with a conventional tandem MS method, with a limit of detection in the low femtomole range for saturated and unsaturated FAs. The developed method was applied to determine FA concentrations in RBC with intra- and interday coefficients of variation below 10%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Evolution of Orbitrap Mass Spectrometry Instrumentation
Eliuk, S., & Makarov, A. (2015) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071114-040325 · Cited by 456
Liu, C., Chikina, M., Deshpande, R., Menk, A. V., Wang, T., Tabib, T., Brunazzi, E. A., Vignali, K. M., Sun, M., Stolz, D. B., et al. (2019) · Immunity · doi:10.1016/j.immuni.2019.06.017 · Cited by 345
Zhu, M., Frank, M. W., Radka, C. D., Jeanfavre, S., Xu, J., Tse, M. W., Pacheco, J. A., Kim, J. S., Pierce, K., Deik, A., et al. (2024) · Cell · doi:10.1016/j.cell.2024.07.029 · Cited by 61
“57 h FAs were quantified by targeted lipidomics using picolylamine-based derivatization 56,58 (representative chromatograms in Figure S4K).”
MethodCharidemou, E., Ashmore, T., Li, X., McNally, B. D., West, J. A., Liggi, S., Harvey, M., Orford, E., & Griffin, J. L. (2019) · JCI Insight · doi:10.1172/jci.insight.124819 · Cited by 52
“Picolinyl ester FA derivatization of organic fractions for LC-MS Picolinyl esters of FAs (PEFAs) were produced using a modification to a method published previously (48) to measure total FA content.”
MethodSelf-citationPiovesana, S., Aita, S. E., Cannazza, G., Capriotti, A. L., Cavaliere, C., Cerrato, A., Guarnaccia, P., Montone, C. M., & Laganà, A. (2021) · Talanta · doi:10.1016/j.talanta.2021.122249 · Cited by 17
Metadata
- Authors
- Li, X., & Franke, A. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-03-23
- Volume
- 83
- Issue
- 8
- Pages
- 3192-3198
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1998276618
- Cited by
- 112
- References
- 0
- FWCI
- 2.35
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved LC−MS Method for the Determination of Fatty Acids in Red Blood Cells by LC−Orbitrap MS. https://app.cochat.ai/papers/10.1021/ac103093w
- The paper
- Li, X., & Franke, A. A. (2011). Improved LC−MS Method for the Determination of Fatty Acids in Red Blood Cells by LC−Orbitrap MS. Analytical Chemistry. https://doi.org/10.1021/ac103093w
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.