Ultra-High-Pressure RPLC Hyphenated to an LTQ-Orbitrap Velos Reveals a Linear Relation between Peak Capacity and Number of Identified Peptides
The DOI matches its Crossref record.
Abstract
Currently, unbiased protein identification is mostly performed by directly coupling reversed-phase liquid chromatography (RPLC) via electrospray ionization to a mass spectrometer. In contrast to the innovations in mass spectrometric instrumentation, cutting-edge technology in RPLC has generally not been well adopted. Here, we describe the effects of increased peak capacities on the number of identified proteins and peptides in complex mixtures utilizing collision-induced dissociation on an LTQ-Orbitrap Velos, providing a rationale for using advanced RPLC technology in LC-MS/MS. Using two different column lengths and gradient times between 1 and 10 h, we found a linear relation between the obtained peak capacities and the number of identified peptides. We identified on average 2516 proteins in the tryptic digest of 1 μg of HeLa lysate using an 8 h gradient on a 50 cm column packed with 2 μm C18 reversed-phase chromatographic material.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kulak, N. A., Pichler, G., Paron, I., Nagaraj, N., & Mann, M. (2014) · Nature Methods · doi:10.1038/nmeth.2834 · Cited by 1,719
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Michalski, A., Damoc, E., Hauschild, J.-P., Lange, O., Wieghaus, A., Makarov, A., Nagaraj, N., Cox, J., Mann, M., & Horning, S. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.011015 · Cited by 832
Quantitative mass spectrometry in proteomics: critical review update from 2007 to the present
Bantscheff, M., Lemeer, S., Savitski, M. M., & Kuster, B. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6203-4 · Cited by 801
Protein Phosphorylation: A Major Switch Mechanism for Metabolic Regulation
Humphrey, S. J., James, D. E., & Mann, M. (2015) · Trends in Endocrinology & Metabolism · doi:10.1016/j.tem.2015.09.013 · Cited by 558
Metadata
- Authors
- Köcher, T., Swart, R., & Mechtler, K.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-04
- Volume
- 83
- Issue
- 7
- Pages
- 2699-2704
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2321437941
- Cited by
- 140
- References
- 0
- FWCI
- 9.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultra-High-Pressure RPLC Hyphenated to an LTQ-Orbitrap Velos Reveals a Linear Relation between Peak Capacity and Number of Identified Peptides. https://app.cochat.ai/papers/10.1021/ac103243t
- The paper
- Köcher, T., Swart, R., & Mechtler, K. (2011). Ultra-High-Pressure RPLC Hyphenated to an LTQ-Orbitrap Velos Reveals a Linear Relation between Peak Capacity and Number of Identified Peptides. Analytical Chemistry. https://doi.org/10.1021/ac103243t
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.