CoChat

Ultra-High-Pressure RPLC Hyphenated to an LTQ-Orbitrap Velos Reveals a Linear Relation between Peak Capacity and Number of Identified Peptides

Köcher, Thomas, Swart, Remco, Mechtler, Karl · 2011 · Analytical Chemistry
Cited by 140

The DOI matches its Crossref record.

Abstract

Currently, unbiased protein identification is mostly performed by directly coupling reversed-phase liquid chromatography (RPLC) via electrospray ionization to a mass spectrometer. In contrast to the innovations in mass spectrometric instrumentation, cutting-edge technology in RPLC has generally not been well adopted. Here, we describe the effects of increased peak capacities on the number of identified proteins and peptides in complex mixtures utilizing collision-induced dissociation on an LTQ-Orbitrap Velos, providing a rationale for using advanced RPLC technology in LC-MS/MS. Using two different column lengths and gradient times between 1 and 10 h, we found a linear relation between the obtained peak capacities and the number of identified peptides. We identified on average 2516 proteins in the tryptic digest of 1 μg of HeLa lysate using an 8 h gradient on a 50 cm column packed with 2 μm C18 reversed-phase chromatographic material.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac103243t

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Köcher, T., Swart, R., & Mechtler, K.
Venue
Analytical Chemistry
Published
2011-04
Volume
83
Issue
7
Pages
2699-2704
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2321437941
Cited by
140
References
0
FWCI
9.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.