Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 367

The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.

Positive Potential Operation of a Cathodic Electrogenerated Chemiluminescence Immunosensor Based on Luminol and Graphene for Cancer Biomarker Detection

Open access
Xu, Shoujiang, Liu, Yang, Wang, Taihong, Li, Jinghong·2011·Analytical Chemistry

Abstract

In this work, we report a cathodic electrogenerated chemiluminescence (ECL) of luminol at a positive potential (ca. 0.05 V vs Ag/AgCl) with a strong light emission on the graphene-modified glass carbon electrode. The resulted graphene-modified electrode offers an excellent platform for high-performance biosensing applications. On the basis of the cathodic ECL signal of luminol on the graphene-modified electrode, an ECL sandwich immunosensor for sensitive detection of cancer biomarkers at low potential was developed with a multiple signal amplification strategy from functionalized graphene and gold nanorods multilabeled with glucose oxidase (GOx) and secondary antibody (Ab(2)). The functionalized graphene improved the electron transfer on the electrode interface and was employed to attach the primary antibody (Ab(1)) due to it large surface area. The gold nanorods were not only used as carriers of secondary antibody (Ab(2)) and GOx but also catalyzed the ECL reaction of luminol, which further amplified the ECL signal of luminol in the presence of glucose and oxygen. The as-proposed low-potential ECL immunosensor exhibited high sensitivity and specificity on the detection of prostate protein antigen (PSA), a biomarker of prostate cancer that was used as a model. A linear relationship between ECL signals and the concentrations of PSA was obtained in the range from 10 pg mL(-1) to 8 ng mL(-1). The detection limit of PSA was 8 pg mL(-1) (signal-to-noise ratio of 3). Moreover, the as-proposed low-potential ECL immunosensor exhibited excellent stability and reproducibility. The graphene-based ECL immunosensor accurately detected PSA concentration in 10 human serum samples from patients demonstrated by excellent correlations with standard chemiluminescence immunoassay. The results suggest that the as-proposed graphene ECL immunosensor will be promising in the point-of-care diagnostics application of clinical screening of cancer biomarkers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac200237j

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 43 references

Cited by

See all 367

Metadata

Authors
Xu, S., Liu, Y., Wang, T., & Li, J.
Venue
Analytical Chemistry
Published
2011-04-22
Volume
83
Issue
10
Pages
3817-3823
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2329183394
Cited by
367
References
43
FWCI
15.28
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Positive Potential Operation of a Cathodic Electrogenerated Chemiluminescence Immunosensor Based on Luminol and Graphene for Cancer Biomarker Detection. https://app.cochat.ai/papers/10.1021/ac200237j
The paper
Xu, S., Liu, Y., Wang, T., & Li, J. (2011). Positive Potential Operation of a Cathodic Electrogenerated Chemiluminescence Immunosensor Based on Luminol and Graphene for Cancer Biomarker Detection. Analytical Chemistry. https://doi.org/10.1021/ac200237j

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.