Optimization and Evaluation of a Sheathless Capillary Electrophoresis–Electrospray Ionization Mass Spectrometry Platform for Peptide Analysis: Comparison to Liquid Chromatography–Electrospray Ionization Mass Spectrometry
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In this study we have evaluated the suitability of a sheathless capillary electrophoresis-electrospray ionization mass spectrometry (CE-ESI-MS) interface with a porous tip as the nanospray emitter for use in peptide analysis. A positively charged capillary coating and 0.1% formic acid as background electrolyte were used for separation upstream from mass spectrometry characterization. The influence of the distance between emitter tip and MS inlet, ESI voltage applied, and of the electroosmotic flow (EOF) on electrospray performance and efficiency of the system was investigated in detail. Under optimized conditions, less than 30 amol of a model peptide (angiotensin I) was required for a detection in the base peak electropherogram and positive identification via tandem MS. Three different cationic capillary coatings were investigated for stability, resolution, and EOF and were found to enable reproducible separations by CE-ESI-MS. After optimizing MS settings, the effectiveness of the CE-ESI-MS method developed was compared with a state-of-the-art nano-liquid chromatography (LC)-ESI-MS method by analyzing Arg-C-digested rat testis linker histones with both systems. With comparable amounts of sample applied, the number of identified peptides increased by more than 60% when using CE-ESI-MS. We found that low molecular mass peptides (below 1400 Da) were preferentially identified by CE-ESI-MS, since this group of peptides poorly interacted with the reversed-phase material in the nano-LC system. Finally, total analysis time in LC-ESI-MS for three runs including equilibration was nearly 4 times longer than that of CE-ESI-MS: 246 versus 66 min.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Capillary electrophoresis applied to proteomic analysis
Fonslow, B. R., & Yates III, J. R. (2009) · Journal of Separation Science · doi:10.1002/jssc.200800592 · Cited by 92
Cited by
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Sun, L., Zhu, G., Zhang, Z., Mou, S., & Dovichi, N. J. (2015) · Journal of Proteome Research · doi:10.1021/acs.jproteome.5b00100 · Cited by 216
“CZEMS/MS produced higher intensity for almost all the overlapped peptides than LC-MS/MS, and on average the peptide signal from CZE is three times higher than that from LC, which indicates the higher sensitivity of CZE-MS/MS, and is in agreement with previous publications.[9,19] We then evaluated the complementarity o…”
Ultrasensitive and Fast Bottom‐up Analysis of Femtogram Amounts of Complex Proteome Digests
Sun, L., Zhu, G., Zhao, Y., Yan, X., Mou, S., & Dovichi, N. J. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201308139 · Cited by 212
Haselberg, R., de Jong, G. J., & Somsen, G. W. (2013) · Analytical Chemistry · doi:10.1021/ac303158f · Cited by 149
Wang, Y., Fonslow, B. R., Wong, C. C. L., Nakorchevsky, A., & Yates, J. R. (2012) · Analytical Chemistry · doi:10.1021/ac301091m · Cited by 144
Metadata
- Authors
- Faserl, K., Sarg, B., Kremser, L., & Lindner, H.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-09-01
- Volume
- 83
- Issue
- 19
- Pages
- 7297-7305
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2318267434
- Cited by
- 153
- References
- 1
- FWCI
- 9.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.