Microscale Phosphoproteome Analysis of 10 000 Cells from Human Cancer Cell Lines
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We developed a miniaturized LC-MS system with a high-recovery phosphopeptide enrichment protocol that allows phosphoproteome analysis of 10(4) cells. In the enrichment protocol, the key step is to add sodium deoxycholate and sodium lauroyl sarcosinate to the buffer solution for protein extraction and digestion and to omit any subsequent desalt/desurfactant step before phosphopeptide enrichment. The phosphopeptides enriched by hydroxy acid-modified metal oxide chromatography (HAMMOC) are directly injected onto a miniaturized LC column using a nitrogen-pressure-driven cell, instead of switching valve-type injectors. The miniaturized analytical column of 25 μm diameter provided a 3.6-fold improvement in sensitivity over the conventional 100 μm diameter column. Overall, our analytical system provided approximately 80-fold improvement on average in the LC-MS response, and we identified 1011 unique phosphorylated sites based on 995 unique phosphopeptides from a single analysis of 10(4) HeLa cells (approximately 1 μg of proteins). This is the most sensitive phosphoproteomics system that has so far been reported for proteome-wide analysis of in vivo phosphorylation in mammalian cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rappsilber, J., Mann, M., & Ishihama, Y. (2007) · Nature Protocols · doi:10.1038/nprot.2007.261 · Cited by 4,641
Self-citationHunter, T. (2000) · Cell · doi:10.1016/s0092-8674(00)81688-8 · Cited by 2,586
Cited by
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Phosphoproteins in extracellular vesicles as candidate markers for breast cancer
Chen, I.-H., Xue, L., Hsu, C.-C., Paez, J. S. P., Pan, L., Andaluz, H., Wendt, M. K., Iliuk, A. B., Zhu, J.-K., & Tao, W. A. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1618088114 · Cited by 472
High-throughput and high-sensitivity phosphoproteomics with the EasyPhos platform
Humphrey, S. J., Karayel, O., James, D. E., & Mann, M. (2018) · Nature Protocols · doi:10.1038/s41596-018-0014-9 · Cited by 358
Illuminating the dark phosphoproteome
Needham, E. J., Parker, B. L., Burykin, T., James, D. E., & Humphrey, S. J. (2019) · Science Signaling · doi:10.1126/scisignal.aau8645 · Cited by 334
Erde, J., Loo, R. R. O., & Loo, J. A. (2014) · Journal of Proteome Research · doi:10.1021/pr4010019 · Cited by 331
Metadata
- Authors
- Masuda, T., Sugiyama, N., Tomita, M., & Ishihama, Y.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-09-19
- Volume
- 83
- Issue
- 20
- Pages
- 7698-7703
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2052574358
- Cited by
- 72
- References
- 2
- FWCI
- 3.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.