The DOI matches its Crossref record.
Lateral Flow Immunochromatographic Assay for Sensitive Pesticide Detection by Using Fe3O4Nanoparticle Aggregates as Color Reagents
Abstract
Magnetic Fe(3)O(4) particle aggregates were prepared by cross-linking Fe(3)O(4) nanoparticles bearing surface carbonyl groups with poly-L-lysine. Upon further coupling with antiparaoxon methyl polyclonal antibody, the resultant particle aggregate-based probes were used in a lateral flow immunochromatographic assay (LFIA) of pesticide residue of paraoxon methyl. The results were compared with that achieved by using the mother Fe(3)O(4) nanoparticles. More quantitative results on the signal amplification effect endowed by the controlled aggregation of Fe(3)O(4) nanoparticles were extracted by relative optical density analysis. Under optimized conditions, a detection limit of 1.7 ng/mL for paraoxon methyl was achieved by using the particle aggregates, which is almost 40-fold lower than that based on the mother Fe(3)O(4) nanoparticles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Koczula, K. M., & Gallotta, A. (2016) · Essays in Biochemistry · doi:10.1042/ebc20150012 · Cited by 1,147
Advances in paper-based point-of-care diagnostics
Hu, J., Wang, S., Wang, L., Li, F., Pingguan-Murphy, B., Lu, T. J., & Xu, F. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.10.075 · Cited by 956
Self-citationDesigns, formats and applications of lateral flow assay: A literature review
Sajid, M., Kawde, A.-N., & Daud, M. (2015) · Journal of Saudi Chemical Society · doi:10.1016/j.jscs.2014.09.001 · Cited by 765
Ultrasensitive and Highly Specific Lateral Flow Assays for Point-of-Care Diagnosis
Liu, Y., Zhan, L., Qin, Z., Sackrison, J., & Bischof, J. C. (2021) · ACS Nano · doi:10.1021/acsnano.0c10035 · Cited by 626
Nanoparticle-based lateral flow biosensors
Quesada-González, D., & Merkoçi, A. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.05.050 · Cited by 597
Metadata
- Authors
- Liu, C., Jia, Q., Yang, C., Qiao, R., Jing, L., Wang, L., Xu, C., & Gao, M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-08-09
- Volume
- 83
- Issue
- 17
- Pages
- 6778-6784
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2054154411
- Cited by
- 233
- References
- 0
- FWCI
- 7.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Lateral Flow Immunochromatographic Assay for Sensitive Pesticide Detection by Using Fe3O4Nanoparticle Aggregates as Color Reagents. https://app.cochat.ai/papers/10.1021/ac201462d
- The paper
- Liu, C., Jia, Q., Yang, C., Qiao, R., Jing, L., Wang, L., Xu, C., & Gao, M. (2011). Lateral Flow Immunochromatographic Assay for Sensitive Pesticide Detection by Using Fe3O4Nanoparticle Aggregates as Color Reagents. Analytical Chemistry. https://doi.org/10.1021/ac201462d
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.