Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 170

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Quantification of Human Uridine-Diphosphate Glucuronosyl Transferase 1A Isoforms in Liver, Intestine, and Kidney Using Nanobore Liquid Chromatography–Tandem Mass Spectrometry

Open access
Harbourt, David E., Fallon, John K., Ito, Shinya, Baba, Takashi, Ritter, Joseph K., Glish, Gary L., Smith, Philip C. · 2012 · Analytical Chemistry

Abstract

Uridine-disphosphate glucuronosyl transferase (UGT) enzymes catalyze the formation of glucuronide conjugates of phase II metabolism. Methods for absolute quantification of UGT1A1 and UGT1A6 were previously established utilizing stable isotope peptide internal standards with liquid chromatography-tandem mass spectrometry (LC-MS/MS). The current method expands upon this by quantifying eight UGT1A isoforms by nanobore high-performance liquid chromatography (HPLC) coupled with a linear ion trap time-of-flight mass spectrometer platform. Recombinant enzyme digests of each of the isoforms were used to determine assay linearity and detection limits. Enzyme expression level in human liver, kidney, and intestinal microsomal protein was determined by extrapolation from spiked stable isotope standards. Intraday and interday variability was <25% for each of the enzyme isoforms. Enzyme expression varied from 3 to 96 pmol/mg protein in liver and intestinal microsomal protein digests. Expression levels of UGT1A7, 1A8, and 1A10 were below detection limits (<1 pmol/mg protein) in human liver microsome (HLMs). In kidney microsomes the expression of UGT1A3 was below detection limits, but levels of UGT1A4, 1A7, 1A9, and 1A10 protein were higher relative to that of liver, suggesting that renal glucuronidation could be a significant factor in renal elimination of glucuronide conjugates. This novel method allows quantification of all nine UGT1A isoforms, many previously not amenable to measurement with traditional methods such as immunologically based assays. Quantitative measurement of proteins involved in drug disposition, such as the UGTs, significantly improves the ability to evaluate and interpret in vitro and in vivo studies in drug development.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac201704a

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Harbourt, D. E., Fallon, J. K., Ito, S., Baba, T., Ritter, J. K., Glish, G. L., & Smith, P. C.
Venue
Analytical Chemistry
Published
2011-12-05
Volume
84
Issue
1
Pages
98-105
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W988420
Cited by
170
References
3
FWCI
17.01
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.