Targeted Luminescent Near-Infrared Polymer-Nanoprobes for In Vivo Imaging of Tumor Hypoxia
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Polystyrene nanoparticles (PS-NPs) were doped with an oxygen-sensitive near-infrared (NIR)-emissive palladium meso-tetraphenylporphyrin and an inert reference dye which are both excitable at 635 nm. The nanosensors were characterized with special emphasis on fundamental parameters such as absolute photoluminescence quantum yield and fluorescence lifetime. The PS-NPs were employed for ratiometric dual-wavelength and lifetime-based photoluminescent oxygen sensing. They were efficiently taken up by cultured murine alveolar macrophages, yielding a characteristic and reversible change in ratiometric response with decreasing oxygen concentration. This correlated with the cellular hypoxic status verified by analysis of hypoxia inducible factor-1α (HIF-1α) accumulation. In addition, the surface of PS-NPs was functionalized with polyethylene glycol (PEG) and the monoclonal antibody herceptin, and their binding to HER2/neu-overexpressing tumor cells was confirmed in vitro. First experiments with tumor-bearing mouse revealed a distinctive ratiometric response within the tumor upon hypoxic condition induced by animal sacrifice. These results demonstrate the potential of these referenced NIR nanosensors for in vitro and in vivo imaging that present a new generation of optical probes for oncology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tumor Hypoxia: Definitions and Current Clinical, Biologic, and Molecular Aspects
Hockel, M., & Vaupel, P. (2001) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/93.4.266 · Cited by 2,662
Fluorescence Lifetime Measurements and Biological Imaging
Berezin, M. Y., & Achilefu, S. (2010) · Chemical Reviews · doi:10.1021/cr900343z · Cited by 2,403
Krohn, K. A., Link, J. M., & Mason, R. P. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.045914 · Cited by 506
Cited by
Relative and absolute determination of fluorescence quantum yields of transparent samples
Würth, C., Grabolle, M., Pauli, J., Spieles, M., & Resch-Genger, U. (2013) · Nature Protocols · doi:10.1038/nprot.2013.087 · Cited by 1,216
Self-citationMacro-/micro-environment-sensitive chemosensing and biological imaging
Yang, Z., Cao, J., He, Y., Yang, J. H., Kim, T., Peng, X., & Kim, J. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00051j · Cited by 875
Ratiometric optical nanoprobes enable accurate molecular detection and imaging
Huang, X., Song, J., Yung, B. C., Huang, X., Xiong, Y., & Chen, X. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00612h · Cited by 820
The Art of Fluorescence Imaging with Chemical Sensors
Schäferling, M. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201105459 · Cited by 721
Self-citationFluorescent Polymer Nanoparticles Based on Dyes: Seeking Brighter Tools for Bioimaging
Reisch, A., & Klymchenko, A. S. (2016) · Small · doi:10.1002/smll.201503396 · Cited by 634
Metadata
- Authors
- Napp, J., Behnke, T., Fischer, L., Würth, C., Wottawa, M., Katschinski, D. M., Alves, F., Resch-Genger, U., & Schäferling, M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-11-02
- Volume
- 83
- Issue
- 23
- Pages
- 9039-9046
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1984751287
- Cited by
- 133
- References
- 3
- FWCI
- 9.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Targeted Luminescent Near-Infrared Polymer-Nanoprobes for In Vivo Imaging of Tumor Hypoxia. https://app.cochat.ai/papers/10.1021/ac201870b
- The paper
- Napp, J., Behnke, T., Fischer, L., Würth, C., Wottawa, M., Katschinski, D. M., Alves, F., Resch-Genger, U., & Schäferling, M. (2011). Targeted Luminescent Near-Infrared Polymer-Nanoprobes for In Vivo Imaging of Tumor Hypoxia. Analytical Chemistry. https://doi.org/10.1021/ac201870b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.