Regulating Oxygen Levels in a Microfluidic Device
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Microfluidic devices made from poly(dimethylsiloxane) (PDMS) are gas permeable and have been used to provide accurate on-chip oxygen regulation. However, pervaporation in PDMS devices can rapidly lead to dramatic changes in solution osmotic pressure. In the present study, we demonstrate a new method for on-chip oxygen control using pre-equilibrated aqueous solutions in gas-control channels to regulate the oxygen content in stagnant microfluidic test chambers. An off-chip gas exchanger is used to equilibrate each control solution prior to entering the chip. Using this strategy, problems due to pervaporation are considerably reduced. An integrated PDMS-based oxygen sensor allows accurate real-time measurements of the oxygen within the microfluidic chamber. The measurements were found to be consistent with predictions from finite-element modeling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hypoxia-Inducible Factors, Stem Cells, and Cancer
Keith, B., & Simon, M. C. (2007) · Cell · doi:10.1016/j.cell.2007.04.019 · Cited by 1,179
Oxygen sensitivity severely limits the replicative lifespan of murine fibroblasts
Parrinello, S., Samper, E., Krtolica, A., Goldstein, J., Melov, S., & Campisi, J. (2003) · Nature Cell Biology · doi:10.1038/ncb1024 · Cited by 1,116
Cited by
Advantages and challenges of microfluidic cell culture in polydimethylsiloxane devices
Halldorsson, S., Lucumi, E., Gómez-Sjöberg, R., & Fleming, R. M. T. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.029 · Cited by 1,027
“To better regulate on-chip oxygen levels or create oxygen gradients, Thomas et al. (2011) developed a microfluidic culture device where precisely oxygenated water is continuously perfused through channels adjacent to cell culture chambers, allowing rapid control of on-chip oxygen levels within…”
BackgroundBiological detection by optical oxygen sensing
Papkovsky, D. B., & Dmitriev, R. I. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60131e · Cited by 444
Tumour-on-a-chip: microfluidic models of tumour morphology, growth and microenvironment
Tsai, H.-F., Trubelja, A., Shen, A. Q., & Bao, G. (2017) · Journal of The Royal Society Interface · doi:10.1098/rsif.2017.0137 · Cited by 214
Methods to study the tumor microenvironment under controlled oxygen conditions
Byrne, M. B., Leslie, M. T., Gaskins, H. R., & Kenis, P. J. A. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.09.006 · Cited by 104
Rivera, K. R., Yokus, M. A., Erb, P. D., Pozdin, V. A., & Daniele, M. (2019) · The Analyst · doi:10.1039/c8an02201a · Cited by 57
Quantitative design strategies for fine control of oxygen in microfluidic systems
Shirure, V. S., Lam, S. F., Shergill, B., Chu, Y. E., Ng, N. R., & George, S. C. (2020) · Lab on a Chip · doi:10.1039/d0lc00350f · Cited by 21
Metadata
- Authors
- Thomas, P. C., Raghavan, S. R., & Forry, S. P.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-10-28
- Volume
- 83
- Issue
- 22
- Pages
- 8821-8824
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2324904310
- Cited by
- 74
- References
- 2
- FWCI
- 3.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.