The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Sensitive Detection of microRNA with Isothermal Amplification and a Single-Quantum-Dot-Based Nanosensor
Abstract
MicroRNAs (miRNAs) play important roles in a wide range of biological processes, and their aberrant expressions are associated with various diseases. Here we develop a rapid, highly sensitive, and specific miRNA assay based on the two-stage exponential amplification reaction (EXPAR) and a single-quantum-dot (QD)-based nanosensor. The two-stage EXPAR involves two templates and two-stage amplification reactions under isothermal conditions. The first template enables the amplification of miRNA, and the second template enables the conversion of miRNA to the reporter oligonucleotide. Importantly, different miRNAs can be converted to the same reporter oligonucleotides, which can hybridize with the same set of capture and reporter probes to form sandwich hybrids. These sandwich hybrids can be assembled on the surface of 605 nm emission QDs (605QDs) to form the 605QD/reporter oligonucleotide/Cy5 complexes, where the 605QD functions as both a fluorescence resonance energy transfer donor and a target concentrator. Upon excitation with a wavelength of 488 nm, distinct Cy5 signals can be observed in the presence of target miRNA. This assay is highly sensitive and specific with a detection limit of 0.1 aM and can even discriminate single-nucleotide differences between miRNA family members. Moreover, in combination with the specific templates, this method can be applied for multiplex miRNA assay by simply using the same set of capture and reporter probes. This highly sensitive and specific assay has potential to become a promising miRNA quantification method in biomedical research and clinical diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Identification of Novel Genes Coding for Small Expressed RNAs
Lagos-Quintana, M., Rauhut, R., Lendeckel, W., & Tuschl, T. (2001) · Science · doi:10.1126/science.1064921 · Cited by 4,956
Cited by
MicroRNA: Function, Detection, and Bioanalysis
Dong, H., Lei, J., Ding, L., Wen, Y., Ju, H., & Zhang, X. (2013) · Chemical Reviews · doi:10.1021/cr300362f · Cited by 1,224
Hildebrandt, N., Spillmann, C. M., Algar, W. R., Pons, T., Stewart, M. H., Oh, E., Susumu, K., Díaz, S. A., Delehanty, J. B., & Medintz, I. L. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00030 · Cited by 730
Zhou, J., Yang, Y., & Zhang, C.-Y. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00049 · Cited by 704
Self-citationAbsolute and Direct MicroRNA Quantification Using DNA–Gold Nanoparticle Probes
Degliangeli, F., Kshirsagar, P., Brunetti, V., Pompa, P. P., & Fiammengo, R. (2014) · Journal of the American Chemical Society · doi:10.1021/ja412152x · Cited by 385
Kilic, T., Erdem, A., Ozsoz, M., & Carrara, S. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.08.007 · Cited by 299
Metadata
- Authors
- Zhang, Y., & Zhang, C.-Y.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-12-13
- Volume
- 84
- Issue
- 1
- Pages
- 224-231
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2044432713
- Cited by
- 235
- References
- 1
- FWCI
- 8.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.