Enhancing the Coverage of the Urinary Metabolome by Sheathless Capillary Electrophoresis-Mass Spectrometry
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Sheathless capillary electrophoresis-mass spectrometry (CE-MS), using a porous tip sprayer, is proposed for the first time for highly sensitive metabolic profiling of human urine. A representative metabolite mixture and human urine were used for evaluation of the sheathless CE-MS platform. For test compounds, relative standard deviations (RSDs) for migration times and peak areas were below 2% and 12%, respectively, and an injection volume of only ∼8 nL resulted in detection limits between 11 and 120 nM. Approximately 900 molecular features were detected in human urine by sheathless CE-MS whereas about 300 molecular features were found with classical sheath-liquid CE-MS. This difference can probably be attributed to an improved ionization efficiency and increased sensitivity at low flow-rate conditions. The integration of transient-isotachophoresis (t-ITP) as an in-capillary preconcentration procedure in sheathless CE-MS further resulted in subnanomolar limits of detection for compounds of the metabolite mixture, and more than 1300 molecular features were observed in urine. Compared to the classical CE-MS approaches, the integration of t-ITP combined with the use of a sheathless interface provides up to 2 orders of magnitude sensitivity improvement. Hence, sheathless CE-MS can be used for in-depth metabolic profiling of biological samples, and we anticipate that this approach will yield unique information in the field of metabolomics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
METLIN—a metabolite mass spectral database
Smith, C. A., Maille, G. O., Want, E. J., Qin, C., Trauger, S. A., Brandon, T. R., Custodio, D. E., Abagyan, R., & Siuzdak, G. (2005) · Therapeutic Drug Monitoring · doi:10.1097/01.ftd.0000179845.53213.39 · Cited by 2,226
Mokaddem, M., Gareil, P., Belgaied, J., & Varenne, A. (2009) · ELECTROPHORESIS · doi:10.1002/elps.200800480 · Cited by 45
Cited by
Lankadurai, B. P., Nagato, E. G., & Simpson, M. J. (2013) · Environmental Reviews · doi:10.1139/er-2013-0011 · Cited by 385
Breadmore, M. C., Shallan, A. I., Rabanes, H. R., Gstoettenmayr, D., Abdul Keyon, A. S., Gaspar, A., Dawod, M., & Quirino, J. P. (2013) · ELECTROPHORESIS · doi:10.1002/elps.201200396 · Cited by 372
Kuehnbaum, N. L., & Britz-McKibbin, P. (2013) · Chemical Reviews · doi:10.1021/cr300484s · Cited by 354
Recent applications of on-line sample preconcentration techniques in capillary electrophoresis
Kitagawa, F., & Otsuka, K. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.10.066 · Cited by 207
Kell, D. B., & Goodacre, R. (2014) · Drug Discovery Today · doi:10.1016/j.drudis.2013.07.014 · Cited by 169
Metadata
- Authors
- Ramautar, R., Busnel, J.-M., Deelder, A. M., & Mayboroda, O. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-12-30
- Volume
- 84
- Issue
- 2
- Pages
- 885-892
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2334639196
- Cited by
- 128
- References
- 2
- FWCI
- 9.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.