Applications of a Catch and Release Electrospray Ionization Mass Spectrometry Assay for Carbohydrate Library Screening
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Applications of a catch and release electrospray ionization mass spectrometry (CaR-ESI-MS) assay for screening carbohydrate libraries against target proteins are described. Direct ESI-MS measurements were performed on solutions containing a target protein (a single chain antibody, an antigen binding fragment, or a fragment of a bacterial toxin) and a library of carbohydrates containing multiple specific ligands with affinities in the 10(3) to 10(6) M(-1) range. Ligands with moderate affinity (10(4) to 10(6) M(-1)) were successfully detected from mixtures containing >200 carbohydrates (at concentrations as low as 0.25 μM each). Additionally, the absolute affinities were estimated from the abundance of free and ligand-bound protein ions determined from the ESI mass spectrum. Multiple low affinity ligands (~10(3) M(-1)) were successfully detected in mixtures containing >20 carbohydrates (at concentrations of ~10 μM each). However, identification of specific interactions required the use of the reference protein method to correct the mass spectrum for the occurrence of nonspecific carbohydrate-protein binding during the ESI process. The release of the carbohydrate ligands, as ions, was successfully demonstrated using collision-induced dissociation performed on the deprotonated ions of the protein-carbohydrate complexes. The use of ion mobility separation, performed on deprotonated carbohydrate ions following their release from the complex, allowed for the positive identification of isomeric ligands.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sun, J., Kitova, E. N., Wang, W., & Klassen, J. S. (2006) · Analytical Chemistry · doi:10.1021/ac0522005 · Cited by 160
Self-citation
Cited by
Characterization of Therapeutic Antibodies and Related Products
Beck, A., Wagner-Rousset, E., Ayoub, D., Van Dorsselaer, A., & Sanglier-Cianférani, S. (2013) · Analytical Chemistry · doi:10.1021/ac3032355 · Cited by 587
Sialic acid-containing glycolipids mediate binding and viral entry of SARS-CoV-2
Nguyen, L., McCord, K. A., Bui, D. T., Bouwman, K. M., Kitova, E. N., Elaish, M., Kumawat, D., Daskhan, G. C., Tomris, I., Han, L., et al. (2022) · Nature Chemical Biology · doi:10.1038/s41589-021-00924-1 · Cited by 259
Self-citationThe diverse and expanding role of mass spectrometry in structural and molecular biology
Lössl, P., van de Waterbeemd, M., & Heck, A. J. (2016) · The EMBO Journal · doi:10.15252/embj.201694818 · Cited by 222
“Third, to verify the relevance of the P-particle model system, the derived kinetic constants were cross-validated by a “proxy protein” ESI-MS method (El-Hawiet et al , 2012a).”
InfluentialNguyen, G. T. H., Bennett, J. L., Liu, S., Hancock, S. E., Winter, D. L., Glover, D. J., & Donald, W. A. (2021) · Journal of the American Chemical Society · doi:10.1021/jacs.1c10408 · Cited by 66
Park, H., Jung, J., Rodrigues, E., Kitova, E. N., Macauley, M. S., & Klassen, J. S. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c02931 · Cited by 28
Self-citation
Metadata
- Authors
- El-Hawiet, A., Shoemaker, G. K., Daneshfar, R., Kitova, E. N., & Klassen, J. S.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-12-06
- Volume
- 84
- Issue
- 1
- Pages
- 50-58
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2318076112
- Cited by
- 56
- References
- 1
- FWCI
- 2.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.