The DOI matches its Crossref record.
Paper-Based Electrochemical Sensing Platform with Integral Battery and Electrochromic Read-Out
Abstract
We report a battery-powered, microelectrochemical sensing platform that reports its output using an electrochromic display. The platform is fabricated based on paper fluidics and uses a Prussian blue spot electrodeposited on an indium-doped tin oxide thin film as the electrochromic indicator. The integrated metal/air battery powers both the electrochemical sensor and the electrochromic read-out, which are in electrical contact via a paper reservoir. The sample activates the battery and the presence of analyte in the sample initiates the color change of the Prussian blue spot. The entire system is assembled on the lab bench, without the need for cleanroom facilities. The applicability of the device to point-of-care sensing is demonstrated by qualitative detection of 0.1 mM glucose and H(2)O(2) in artificial urine samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
Electrochromics for smart windows: Oxide-based thin films and devices
Granqvist, C. G. (2014) · Thin Solid Films · doi:10.1016/j.tsf.2014.02.002 · Cited by 1,080
Advances in paper-based point-of-care diagnostics
Hu, J., Wang, S., Wang, L., Li, F., Pingguan-Murphy, B., Lu, T. J., & Xu, F. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.10.075 · Cited by 956
Energy storage systems: a review
Mitali, J., Dhinakaran, S., & Mohamad, A. A. (2022) · Energy Storage and Saving · doi:10.1016/j.enss.2022.07.002 · Cited by 911
Graphene-Paper Pressure Sensor for Detecting Human Motions
Tao, L.-Q., Zhang, K.-N., Tian, H., Liu, Y., Wang, D.-Y., Chen, Y.-Q., Yang, Y., & Ren, T.-L. (2017) · ACS Nano · doi:10.1021/acsnano.7b02826 · Cited by 738
Metadata
- Authors
- Liu, H., & Crooks, R. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-02-22
- Volume
- 84
- Issue
- 5
- Pages
- 2528-2532
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1988399249
- Cited by
- 234
- References
- 0
- FWCI
- 16.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Paper-Based Electrochemical Sensing Platform with Integral Battery and Electrochromic Read-Out. https://app.cochat.ai/papers/10.1021/ac203457h
- The paper
- Liu, H., & Crooks, R. M. (2012). Paper-Based Electrochemical Sensing Platform with Integral Battery and Electrochromic Read-Out. Analytical Chemistry. https://doi.org/10.1021/ac203457h
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.