The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Application of Electrochemically Reduced Graphene Oxide on Screen-Printed Ion-Selective Electrode
Abstract
In this study, a novel disposable all-solid-state ion-selective electrode using graphene as the ion-to-electron transducer was developed. The graphene film was prepared on screen-printed electrode directly from the graphene oxide dispersion by a one-step electrodeposition technique. Cyclic voltammetry and electrochemical impedance spectroscopy were employed to demonstrate the large double layer capacitance and fast charge transfer of the graphene film modified electrode. On the basis of these excellent properties, an all-solid-state calcium ion-selective electrode as the model was constructed using the calcium ion-selective membrane and graphene film modified electrode. The mechanism about the graphene promoting the ion-to-electron transformation was investigated in detail. The disposable electrode exhibited a Nernstian slope (29.1 mV/decade), low detection limit (10(-5.8) M), and fast response time (less than 10 s). With the high hydrophobic character of graphene materials, no water film was formed between the ion-selective membrane and the underlying graphene layer. Further studies revealed that the developed electrode was insensitive to light, oxygen, and redox species. The use of the disposable electrode for real sample analysis obtained satisfactory results, which made it a promising alternative in routine sensing applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Graphene-based nanomaterials and their electrochemistry
Pumera, M. (2010) · Chemical Society Reviews · doi:10.1039/c002690p · Cited by 1,117
Bobacka, J. (1999) · Analytical Chemistry · doi:10.1021/ac990497z · Cited by 686
Preparation of all solid-state potentiometric ion sensors with polymer-CNT composites
Zhu, J., Qin, Y., & Zhang, Y. (2009) · Electrochemistry Communications · doi:10.1016/j.elecom.2009.06.025 · Cited by 98
Cited by
Electrochemistry of Graphene and Related Materials
Ambrosi, A., Chua, C. K., Bonanni, A., & Pumera, M. (2014) · Chemical Reviews · doi:10.1021/cr500023c · Cited by 1,208
Wang, S., Wu, Y., Gu, Y., Li, T., Luo, H., Li, L.-H., Bai, Y., Li, L., Liu, L., Cao, Y., et al. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b01560 · Cited by 174
Tsai, Y.-F., Luo, W.-I., Chang, J.-L., Chang, C.-W., Chuang, H.-C., Ramu, R., Wei, G.-T., Zen, J.-M., & Yu, S. S.-F. (2017) · Scientific Reports · doi:10.1038/s41598-017-08610-w · Cited by 31
Metadata
- Authors
- Ping, J., Wang, Y., Ying, Y., & Wu, J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-03-12
- Volume
- 84
- Issue
- 7
- Pages
- 3473-3479
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2313505840
- Cited by
- 199
- References
- 3
- FWCI
- 7.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.