The DOI matches its Crossref record.
One-Pot Synthesis of Aptamer-Functionalized Silver Nanoclusters for Cell-Type-Specific Imaging
Abstract
As an emerging category of fluorescent metal nanoclusters, oligonucleotide-templated silver nanoclusters (Ag NCs) have attracted a lot of interest and have shown wide application in biorelated disciplines. However, the weak fluorescence emission and poor permeability to cell membranes tethered further intracellular applications of Ag NCs. AS1411 is an antiproliferative G-rich phosphodiester oligonucleotide and currently an anticancer agent under phase II clinical trials. Herein, we present a strategy to synthesize AS1411-functionalized Ag NCs with excellent fluorescence through a facile one-pot process. Confocal laser scanning microscopy and Z-axis scanning confirmed that the AS1411-functionalized Ag NCs could be internalized into MCF-7 human breast cancer cells and were able to specifically stain nuclei with red color. To our surprise, 3-[4,5-dimethylthiazol-z-yl]-2,5-diphenyltetrazolium bromide (MTT) assay demonstrated the Ag NCs were cytocompatible and showed better inhibition effects than pure AS1411 on MCF-7 human breast cancer cells. In addition, a universal design of the oligonucleotide scaffold for synthesis of Ag NCs was extended to other aptamers, such as Sgc8c and mucin 1 aptamer. Due to the facile synthesis procedure and capability of specific target recognition, this fluorescent platform will potentially broaden the applications of Ag NCs in biosensing and biological imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Metal nanoclusters: New fluorescent probes for sensors and bioimaging
Zhang, L., & Wang, E. (2014) · Nano Today · doi:10.1016/j.nantod.2014.02.010 · Cited by 976
Metal nanoclusters: novel probes for diagnostic and therapeutic applications
Tao, Y., Li, M., Ren, J., & Qu, X. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00607d · Cited by 736
Quantum dots for fluorescent biosensing and bio-imaging applications
Li, J., & Zhu, J.-J. (2013) · The Analyst · doi:10.1039/c3an36705c · Cited by 369
Self-citationFunctionalization of metal nanoclusters for biomedical applications
Song, X.-R., Goswami, N., Yang, H.-H., & Xie, J. (2016) · The Analyst · doi:10.1039/c6an00773b · Cited by 327
Kan, X., Wang, J., Li, Y., Li, D., Li, F., Huang, C., & Liu, P. (2026) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2025.115397 · Cited by 3
Metadata
- Authors
- Li, J., Zhong, X., Cheng, F., Zhang, J.-R., Jiang, L.-P., & Zhu, J.-J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-04-17
- Volume
- 84
- Issue
- 9
- Pages
- 4140-4146
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2106955159
- Cited by
- 193
- References
- 0
- FWCI
- 11.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: One-Pot Synthesis of Aptamer-Functionalized Silver Nanoclusters for Cell-Type-Specific Imaging. https://app.cochat.ai/papers/10.1021/ac3003402
- The paper
- Li, J., Zhong, X., Cheng, F., Zhang, J.-R., Jiang, L.-P., & Zhu, J.-J. (2012). One-Pot Synthesis of Aptamer-Functionalized Silver Nanoclusters for Cell-Type-Specific Imaging. Analytical Chemistry. https://doi.org/10.1021/ac3003402
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.