Colorimetric Paper Bioassay for the Detection of Phenolic Compounds

Alkasir, Ramiz S. J., Ornatska, Maryna, Andreescu, Silvana·2012·Analytical Chemistry

Abstract

A new type of paper based bioassay for the colorimetric detection of phenolic compounds including phenol, bisphenol A, catechol and cresols is reported. The sensor is based on a layer-by-layer (LbL) assembly approach formed by alternatively depositing layers of chitosan and alginate polyelectrolytes onto filter paper and physically entrapping the tyrosinase enzyme in between these layers. The sensor response is quantified as a color change resulting from the specific binding of the enzymatically generated quinone to the multilayers of immobilized chitosan on the paper. The color change can be quantified with the naked eye but a digitalized picture can also be used to provide more sensitive comparison to a calibrated color scheme. The sensor was optimized with respect to the number of layers, pH, enzyme, chitosan and alginate amounts. The colorimetric response was concentration dependent, with a detection limit of 0.86 (±0.1) μg/L for each of the phenolic compounds tested. The response time required for the sensor to reach steady-state color varied between 6 and 17 min depending on the phenolic substrate. The sensor showed excellent storage stability at room temperature for several months (92% residual activity after 260 days storage) and demonstrated good functionality in real environmental samples. A procedure to mass-produce the bioactive sensors by inkjet printing the LbL layers of polyelectrolyte and enzyme on paper is demonstrated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac301110d

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 182

Metadata

Authors
Alkasir, R. S. J., Ornatska, M., & Andreescu, S.
Venue
Analytical Chemistry
Published
2012-11-05
Volume
84
Issue
22
Pages
9729-9737
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2323819663
Cited by
182
References
1
FWCI
8.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Colorimetric Paper Bioassay for the Detection of Phenolic Compounds. https://app.cochat.ai/papers/10.1021/ac301110d
The paper
Alkasir, R. S. J., Ornatska, M., & Andreescu, S. (2012). Colorimetric Paper Bioassay for the Detection of Phenolic Compounds. Analytical Chemistry. https://doi.org/10.1021/ac301110d

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.