CoChat

Fluorine Speciation Analysis Using Reverse Phase Liquid Chromatography Coupled Off-Line to Continuum Source Molecular Absorption Spectrometry (CS-MAS): Identification and Quantification of Novel Fluorinated Organic Compounds in Environmental and Biological Samples

Qin, Zhiwei, McNee, David, Gleisner, Heike, Raab, Andrea, Kyeremeh, Kwaku, Jaspars, Marcel, Krupp, Eva, Deng, Hai, Feldmann, Jörg · 2012 · Analytical Chemistry
Cited by 63

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Driven by increasing demand for the monitoring of industrial perfluorinated compounds (PFCs), the identification of novel fluorine containing compounds (FOCs) and the tracking of organofluorine drugs and their degradation products, there is a clear need for sensitive, fluorine-specific detection of unknown FOCs. Here we report the first ever direct fluorine-specific (speciation) method; capable of individually detecting untargeted FOCs in environmental and biological samples through the application of continuum source molecular absorption spectrometry (CS-MAS) using a commercial CS-AAS. Two model FOCs (2,4,6, trifluorobenzoic acid (TFBA) and 5-fluoroindol-5-carboxylic acid (FICA)) were used, achieving fluorine-specific detection across a range of 0.1 to 300 ng/mL fluorine, corresponding to a limit of detection of 4 pg F and 5.26 nM for both compounds. Both TFBA and FICA showed a similar response to CS-MAS detection, potentially enabling the quantification of fluorine content in novel FOCs without having molecular standards available. This paper also reports the use of reverse-phase high performance liquid chromatography (RP-HPLC) coupled off-line with CS-MAS for the identification of single organofluorines in a mixture of FOCs via fraction collection. The linear range of both FOCs was determined to be from 1 to 500 ng/mL. The limits of detection of those species were just above 1 ng/mL (100 pg) and can therefore compete with targeted analytical methods such as ESI-MS. Finally, as a proof of principle the analysis of a fluoride-containing groundwater sample from Ghana demonstrated that this method can be used in the detection of novel FOCs, with identification achieved through parallel ESI-MS. Coupled HPLC-CS-MAS/ESI-MS is the first analytical methodology capable of selectively detecting and identifying novel FOCs, making possible the quantification of all fluorine containing compounds in one sample. This is the necessary analytical requirement to perform fluoronomics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac301201y

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 63

Metadata

Authors
Qin, Z., McNee, D., Gleisner, H., Raab, A., Kyeremeh, K., Jaspars, M., Krupp, E., Deng, H., & Feldmann, J.
Venue
Analytical Chemistry
Published
2012-06-28
Volume
84
Issue
14
Pages
6213-6219
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2072104416
Cited by
63
References
1
FWCI
4.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.