Cited by 209Per- and polyfluoroalkyl substances researchMass Spectrometry Techniques and ApplicationsFluorine in Organic Chemistry

Discovery of C 5 –C 17 Poly- and Perfluoroalkyl Substances in Water by In-Line SPE-HPLC-Orbitrap with In-Source Fragmentation Flagging

Liu, Yanna, Pereira, Alberto Dos Santos, Martin, Jonathan W.·2015·Analytical Chemistry

Abstract

The presence of unknown organofluorine compounds in environmental samples has prompted the development of nontargeted analytical methods capable of detecting new perfluoroalkyl and polyfluoroalkyl substances (PFASs). By combining high volume injection with high performance liquid chromatography (HPLC) and ultrahigh resolution Orbitrap mass spectrometry, a sensitive (0.003-0.2 ng F/mL for model mass-labeled PFASs) untargeted workflow was developed for discovery and characterization of novel PFASs in water. In the first step, up to 5 mL of water is injected to in-line solid phase extraction, chromatographed by HPLC, and detected by electrospray ionization with mass spectral acquisition in parallel modes cycling back and forth: (i) full scan with ultrahigh resolving power (RP = 120,000, mass accuracy ≤3 ppm), and (ii) in-source fragmentation flagging scans designed to yield marker fragment ions including [C2F5](-) (m/z 118.992), [C3F7](-) (m/z 168.988), [SO4H](-) (m/z 96.959), and [Cl](-) (m/z 34.9). For flagged PFASs, plausible empirical formulas were generated from accurate masses, isotopic patterns, and fragment ions. In the second step, another injection is made to collect high resolution MS/MS spectra of suspect PFAS ions, allowing further confirmation of empirical formulas while also enabling preliminary structural characterization. The method was validated by applying it to an industrial wastewater, and 36 new PFASs were discovered. Of these, 26 were confidently assigned to 3 new PFAS classes that have not previously been reported in the environment: polyfluorinated sulfates (CnFn+3Hn-2SO4(-); n = 5, 7, 9, 11, 13, and 15), chlorine substituted perfluorocarboxylates (ClCnF2nCO2(-); n = 4-11), and hydro substituted perfluorocarboxylates (HCnF2nCO2(-); n = 5-16). Application of the technique to environmental water samples is now warranted.

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.5b00039

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Liu, Y., Pereira, A. D. S., & Martin, J. W.
Affiliations
University of Alberta (CA)
Corresponding author
Martin, Jonathan W.
Venue
Analytical Chemistry
Published
2015-04-09
Volume
87
Issue
8
Pages
4260-4268
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W1979435857
Cited by
209
References
5
Citations by year
2026: 14 · 2025: 24 · 2024: 17 · 2023: 26 · 2022: 34 · 2021: 21 · 2020: 22 · 2019: 19 · 2018: 9 · 2017: 11 · 2016: 11 · 2015: 1
FWCI
7.86
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Ministry of Health and Wellness, Government of Alberta
  • China Scholarship Council
  • Natural Sciences and Engineering Research Council of Canada
Topics
  • Physical Sciences › Environmental Science › Environmental Chemistry › Per- and polyfluoroalkyl substances research
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Fluorine in Organic Chemistry
Keywords
perfluorinated compounds, polyfluoroalkyl substances, non-targeted analysis, water analysis, industrial wastewater, organofluorine compounds, empirical formula determination
MeSH terms
Chromatography, High Pressure Liquid, Fluorocarbons, Water Pollutants, Chemical, Solid Phase Extraction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review