The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Trace and Label-Free MicroRNA Detection Using Oligonucleotide Encapsulated Silver Nanoclusters as Probes
Abstract
A simple, sensitive, and label-free method for microRNA (miRNA) biosensing was described using oligonucleotide encapsulated silver nanoclusters (Ag-NCs) as effective electrochemical probes. The functional oligonucleotide probe integrates both recognition sequence for hybridization and template sequence for in situ synthesis of Ag-NCs, which appears to possess exceptional metal mimic enzyme properties for catalyzing H(2)O(2) reduction. The miRNA assay employs gold electrodes to immobilize the molecular beacon (MB) probe. After the MB probe subsequently hybridizes with the target and functional probe, the oligonucleotide encapsulated Ag-NCs are brought to the electrode surface and produce a detection signal, in response to H(2)O(2) reduction. An electrochemical miRNA biosensor down to 67 fM with a linear range of 5 orders of magnitude was obtained. Meanwhile, the MB probe allows the biosensor to detect the target with high selectivity. The Ag-NCs-based approach provides a novel avenue to detect miRNA with high sensitivity and selectivity while avoiding laborious label and signal amplification. It is convinced that rational introduction of signal amplification strategy to the Ag-NCs-based bioanalysis can further improve the sensitivity. To our best knowledge, this is the first application of the electrocatalytic activity of Ag-NCs in bioanalysis, which would be attractive for genetic analysis and clinic biomedical application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The functions of animal microRNAs
Ambros, V. (2004) · Nature · doi:10.1038/nature02871 · Cited by 10,728
Cited by
Metal nanoclusters: New fluorescent probes for sensors and bioimaging
Zhang, L., & Wang, E. (2014) · Nano Today · doi:10.1016/j.nantod.2014.02.010 · Cited by 976
Electrochemical Methods for the Analysis of Clinically Relevant Biomolecules
Labib, M., Sargent, E. H., & Kelley, S. O. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00220 · Cited by 976
Synthesis, Assembly, and Applications of Hybrid Nanostructures for Biosensing
Zhang, S., Geryak, R., Geldmeier, J., Kim, S., & Tsukruk, V. V. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00088 · Cited by 340
Noble Metal Clusters: Applications in Energy, Environment, and Biology
Mathew, A., & Pradeep, T. (2014) · Particle & Particle Systems Characterization · doi:10.1002/ppsc.201400033 · Cited by 328
Kilic, T., Erdem, A., Ozsoz, M., & Carrara, S. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.08.007 · Cited by 299
Metadata
- Authors
- Dong, H., Jin, S., Ju, H., Hao, K., Xu, L.-P., Lu, H., & Zhang, X.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-09-28
- Volume
- 84
- Issue
- 20
- Pages
- 8670-8674
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2129106528
- Cited by
- 177
- References
- 1
- FWCI
- 9.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.