The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Digital Microfluidic Magnetic Separation for Particle-Based Immunoassays
Abstract
We introduce a new format for particle-based immunoassays relying on digital microfluidics (DMF) and magnetic forces to separate and resuspend antibody-coated paramagnetic particles. In DMF, fluids are electrostatically controlled as discrete droplets (picoliters to microliters) on an array of insulated electrodes. By applying appropriate sequences of potentials to these electrodes, multiple droplets can be manipulated simultaneously and various droplet operations can be achieved using the same device design. This flexibility makes DMF well-suited for applications that require complex, multistep protocols such as immunoassays. Here, we report the first particle-based immunoassay on DMF without the aid of oil carrier fluid to enable droplet movement (i.e., droplets are surrounded by air instead of oil). This new format allowed the realization of a novel on-chip particle separation and resuspension method capable of removing greater than 90% of unbound reagents in one step. Using this technique, we developed methods for noncompetitive and competitive immunoassays, using thyroid stimulating hormone (TSH) and 17β-estradiol (E2) as model analytes, respectively. We show that, compared to conventional methods, the new DMF approach reported here reduced reagent volumes and analysis time by 100-fold and 10-fold, respectively, while retaining a level of analytical performance required for clinical screening. Thus, we propose that the new technique has great potential for eventual use in a fast, low-waste, and inexpensive instrument for the quantitative analysis of proteins and small molecules in low sample volumes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Clinical Significance of Subclinical Thyroid Dysfunction
Biondi, B., & Cooper, D. S. (2008) · Endocrine Reviews · doi:10.1210/er.2006-0043 · Cited by 1,418
The Evidence for a Narrower Thyrotropin Reference Range Is Compelling
Wartofsky, L., & Dickey, R. A. (2005) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2005-0455 · Cited by 424
Stricker, R., Eberhart, R., Chevailler, M.-C., Quinn, F. A., Bischof, P., & Stricker, R. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.160 · Cited by 392
Cited by
Magnetic digital microfluidics – a review
Zhang, Y., & Nguyen, N.-T. (2017) · Lab on a Chip · doi:10.1039/c7lc00025a · Cited by 364
Leng, Y., Sun, K., Chen, X., & Li, W. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00382a · Cited by 258
Digital microfluidics for spheroid-based invasion assays
Bender, B. F., Aijian, A. P., & Garrell, R. L. (2016) · Lab on a Chip · doi:10.1039/c5lc01569c · Cited by 49
Metadata
- Authors
- Ng, A. H. C., Choi, K., Luoma, R. P., Robinson, J. M., & Wheeler, A. R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-09-26
- Volume
- 84
- Issue
- 20
- Pages
- 8805-8812
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2041672535
- Cited by
- 187
- References
- 3
- FWCI
- 14.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Digital Microfluidic Magnetic Separation for Particle-Based Immunoassays. https://app.cochat.ai/papers/10.1021/ac3020627
- The paper
- Ng, A. H. C., Choi, K., Luoma, R. P., Robinson, J. M., & Wheeler, A. R. (2012). Digital Microfluidic Magnetic Separation for Particle-Based Immunoassays. Analytical Chemistry. https://doi.org/10.1021/ac3020627
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.