Fully-Automated Fluorimetric Determination of Aluminum in Seawater by In-Syringe Dispersive Liquid–Liquid Microextraction Using Lumogallion
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
A sensitive and selective automated in-syringe dispersive liquid-liquid microextraction (DLLME) method is presented. It was successfully applied to the determination of aluminum in coastal seawater samples. The complete analytical procedure including sampling, buffering, reaction of the analyte with fluorescence reagent lumogallion (LMG), extraction, phase separation, and quantification was completely automized and carried out within 4 min. DLLME was done using n-hexanol as an extracting solvent and ethanol as a dispersing solvent in a 1:8 v/v percent mixture. The Al-LMG complex was extracted by an organic solvent and separated from the aqueous phase within the syringe of an automated syringe pump. Two devices were specially developed for this work. These were (a) the fluorescence detector and accompanying flow cell for the organic phase enriched with the reaction product and (b) a heating device integrated into the holding coil to accelerate the slow reaction kinetics. The limits of detection (3σ) and quantification (10σ) were 8.0 ± 0.5 nmol L(-1) and 26.7 ± 1.6 nmol L(-1), respectively. The relative standard deviation for eight replicate determinations of 200 nmol L(-1) Al(3+) was <1.5%. The calibration graph using the preconcentration system was linear up to 1000 nmol L(-1) with a correlation coefficient of 0.999. Ambient concentrations of samples were quantifiable with found concentrations ranging from 43 to 142 nmol L(-1). Standard additions gave analyte recoveries from 97% to 113% proving the general applicability and adequateness of the analyzer system to real sample analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Anthemidis, A. N., & Ioannou, K.-I. G. (2009) · Talanta · doi:10.1016/j.talanta.2009.03.005 · Cited by 258
Rezaee, M., Yamini, Y., Khanchi, A., Faraji, M., & Saleh, A. (2010) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2010.02.006 · Cited by 166
Automated on-line dispersive liquid–liquid microextraction based on a sequential injection system
Andruch, V., Acebal, C. C., Škrlíková, J., Sklenářová, H., Solich, P., Balogh, I. S., Billes, F., & Kocúrová, L. (2012) · Microchemical Journal · doi:10.1016/j.microc.2011.09.006 · Cited by 115
Abdolmohammad-Zadeh, H., & Sadeghi, G. H. (2010) · Talanta · doi:10.1016/j.talanta.2010.01.012 · Cited by 86
Cited by
Green aspects, developments and perspectives of liquid phase microextraction techniques
Spietelun, A., Marcinkowski, Ł., de la Guardia, M., & Namieśnik, J. (2014) · Talanta · doi:10.1016/j.talanta.2013.10.050 · Cited by 333
Recent developments in dispersive liquid–liquid microextraction
Saraji, M., & Boroujeni, M. K. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7467-z · Cited by 232
“In other work, the combination of in-syringeDLLME and a fluorescence flow cell was used for the determination of aluminum in costal seawater [191].”
Mousavi, L., Tamiji, Z., & Khoshayand, M. R. (2018) · Talanta · doi:10.1016/j.talanta.2018.08.002 · Cited by 195
Metal applications of liquid-phase microextraction
Aguirre, M. Á., Baile, P., Vidal, L., & Canals, A. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.11.032 · Cited by 67
Automated Agitation-Assisted Demulsification Dispersive Liquid–Liquid Microextraction
Guo, L., Chia, S. H., & Lee, H. K. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03919 · Cited by 41
Metadata
- Authors
- Suárez, R., Horstkotte, B., Duarte, C. M., & Cerdà, V.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-10-10
- Volume
- 84
- Issue
- 21
- Pages
- 9462-9469
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2093195155
- Cited by
- 52
- References
- 5
- FWCI
- 7.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.