The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
In Vivo Noninvasive Monitoring of Glucose Concentration in Human Epidermis by Mid-Infrared Pulsed Photoacoustic Spectroscopy
Abstract
The noninvasive determination of glucose in the interstitial layer of the human skin by mid-infrared spectroscopy is reported. The sensitivity for this measurement was obtained by combining the high pulse energy from an external cavity quantum cascade laser (EC-QCL) tunable in the infrared glucose fingerprint region (1000-1220 cm(-1)) focused on the skin, with a detection of the absorbance process by photoacoustic spectroscopy in the ultrasound region performed by a gas cell coupled to the skin. This combination facilitates a quantitative measurement for concentrations of skin glucose in the range from <50 mg/dL to >300 mg/dL, which is the relevant range for the glucose monitoring in diabetes patients. Since the interstitial fluid glucose level is representative of the blood glucose level and follows it without significant delay (<10 min), this method could be applied to establish a noninvasive, painless glucose measurement procedure that is urgently awaited by diabetes patients. We report here the design of the photoacoustic experiments, the spectroscopy of glucose in vivo, and the calibration method for the quantitative determination of glucose in skin. Finally, a preliminary test with healthy volunteers and volunteers suffering from diabetes mellitus demonstrates the viability of a noninvasive glucose monitoring for patients based on the combination of infrared QCL and photoacoustic detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Glucose sensors: a review of current and emerging technology
Oliver, N. S., Toumazou, C., Cass, A. E. G., & Johnston, D. G. (2009) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02642.x · Cited by 584
Cited by
Tutorial on photoacoustic tomography
Zhou, Y., Yao, J., & Wang, L. V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.6.061007 · Cited by 421
Advances in Mid-Infrared Spectroscopy for Chemical Analysis
Haas, J., & Mizaikoff, B. (2016) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071015-041507 · Cited by 385
Wearable and Miniaturized Sensor Technologies for Personalized and Preventive Medicine
Tricoli, A., Nasiri, N., & De, S. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201605271 · Cited by 346
Advances in wearable chemical sensor design for monitoring biological fluids
Matzeu, G., Florea, L., & Diamond, D. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.01.077 · Cited by 300
Bogue-Jimenez, B., Huang, X., Powell, D., & Doblas, A. (2022) · Sensors · doi:10.3390/s22093534 · Cited by 24
Metadata
- Authors
- Pleitez, M. A., Lieblein, T., Bauer, A., Hertzberg, O., von Lilienfeld-Toal, H., & Mäntele, W.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-12-26
- Volume
- 85
- Issue
- 2
- Pages
- 1013-1020
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1995581381
- Cited by
- 196
- References
- 1
- FWCI
- 2.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.