The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Quantitative MALDI Tandem Mass Spectrometric Imaging of Cocaine from Brain Tissue with a Deuterated Internal Standard
Abstract
Mass spectrometric imaging (MSI) is an analytical technique used to determine the distribution of individual analytes within a given sample. A wide array of analytes and samples can be investigated by MSI, including drug distribution in rats, lipid analysis from brain tissue, protein differentiation in tumors, and plant metabolite distributions. Matrix-assisted laser desorption/ionization (MALDI) is a soft ionization technique capable of desorbing and ionizing a large range of compounds, and it is the most common ionization source used in MSI. MALDI mass spectrometry (MS) is generally considered to be a qualitative analytical technique because of significant ion-signal variability. Consequently, MSI is also thought to be a qualitative technique because of the quantitative limitations of MALDI coupled with the homogeneity of tissue sections inherent in an MSI experiment. Thus, conclusions based on MS images are often limited by the inability to correlate ion signal increases with actual concentration increases. Here, we report a quantitative MSI method for the analysis of cocaine (COC) from brain tissue using a deuterated internal standard (COC-d(3)) combined with wide-isolation MS/MS for analysis of the tissue extracts with scan-by-scan COC-to-COC-d(3) normalization. This resulted in significant improvements in signal reproducibility and calibration curve linearity. Quantitative results from the MSI experiments were compared with quantitative results from liquid chromatography (LC)-MS/MS results from brain tissue extracts. Two different quantitative MSI techniques (standard addition and external calibration) produced quantitative results comparable to LC-MS/MS data. Tissue extracts were also analyzed by MALDI wide-isolation MS/MS, and quantitative results were nearly identical to those from LC-MS/MS. These results clearly demonstrate the necessity for an internal standard for quantitative MSI experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular Imaging of Biological Samples: Localization of Peptides and Proteins Using MALDI-TOF MS
Caprioli, R. M., Farmer, T. B., & Gile, J. (1997) · Analytical Chemistry · doi:10.1021/ac970888i · Cited by 2,234
Cited by
Aichler, M., & Walch, A. (2015) · Laboratory Investigation · doi:10.1038/labinvest.2014.156 · Cited by 457
Mass Spectrometry Imaging of Biomolecular Information
Spengler, B. (2015) · Analytical Chemistry · doi:10.1021/ac504543v · Cited by 290
MALDI imaging mass spectrometry: Spatial molecular analysis to enable a new age of discovery
Gessel, M. M., Norris, J. L., & Caprioli, R. M. (2014) · Journal of Proteomics · doi:10.1016/j.jprot.2014.03.021 · Cited by 276
Körber, A., Anthony, I. G. M., & Heeren, R. M. A. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.4c05249 · Cited by 88
Self-citation
Metadata
- Authors
- Pirman, D. A., Reich, R. F., Kiss, A., Heeren, R. M. A., & Yost, R. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-12-24
- Volume
- 85
- Issue
- 2
- Pages
- 1081-1089
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2130676293
- Cited by
- 182
- References
- 1
- FWCI
- 7.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative MALDI Tandem Mass Spectrometric Imaging of Cocaine from Brain Tissue with a Deuterated Internal Standard. https://app.cochat.ai/papers/10.1021/ac302960j
- The paper
- Pirman, D. A., Reich, R. F., Kiss, A., Heeren, R. M. A., & Yost, R. A. (2013). Quantitative MALDI Tandem Mass Spectrometric Imaging of Cocaine from Brain Tissue with a Deuterated Internal Standard. Analytical Chemistry. https://doi.org/10.1021/ac302960j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.