Cited by 2,234Mass Spectrometry Techniques and ApplicationsAdvanced Proteomics Techniques and ApplicationsIon-surface interactions and analysis

Molecular Imaging of Biological Samples: Localization of Peptides and Proteins Using MALDI-TOF MS

Caprioli, Richard M., Farmer, Terry B., Gile, Jocelyn·1997·Analytical Chemistry

Abstract

Matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) has been used to generate ion images of samples in one or more mass-to-charge (m/z) values, providing the capability of mapping specific molecules to two-dimensional coordinates of the original sample. The high sensitivity of the technique (low-femtomole to attomole levels for proteins and peptides) allows the study of organized biochemical processes occurring in, for example, mammalian tissue sections. The mass spectrometer is used to determine the molecular weights of the molecular in the surface layers of the tissue. Molecules desorbed from the sample typically are singly protonated, giving an ion at (M + H)+, where M is the molecular mass. The procedure involves coating the tissue section, or a blotted imprint of the section, with a thin layer of energy-absorbing matrix and then analyzing the sample to produce an ordered array of mass spectra, each containing nominal m/z values typically covering a range of over 50,000 Da. Images can be displayed in individual m/z values as a selected ion image, which would localize individual compounds in the tissue, or as summed ion images. MALDI ion images of tissue sections can be obtained directly from tissue slices following preparative steps, and this is demonstrated for the mapping of insulin contained in an islet in a section of rat pancreas, hormone peptides in a small area of a section of rat pituitary, and a small protein bound to the membrane of human mucosa cells. Alternatively, imprints of the tissue can be analyzed by blotting the tissue sections on specially prepared targets containing an adsorbent material, e.g., C-18 coated resin beads. Peptides and small proteins bind to the C-18 and create a positive imprint of the tissue which can then be imaged by the mass spectrometer. This is demonstrated for the MALDI ion image analysis of regions of rat splenic pancreas and for an area of rat pituitary traversing the anterior, intermediate, and posterior regions where localized peptides were mapped. In a single spectrum from the anterior/intermediate lobe of a rat pituitary print, over 50 ions corresponding to the peptides present in this tissue were observed as well as precursors, isoforms, and metabolic fragments.

Integrity signals

Registry

Crossref · 10.1021/ac970888i

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
Caprioli, R. M., Farmer, T. B., & Gile, J.
Affiliations
Department of Biochemistry and Molecular Biology and Analytical Chemistry Center, University of Texas Medical School, 6431 Fannin Street, Houston, Texas 77030
Venue
Analytical Chemistry
Published
1997-12-01
Volume
69
Issue
23
Pages
4751-4760
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2033278243
Cited by
2,234
References
0
Citations by year
2026: 79 · 2025: 100 · 2024: 97 · 2023: 89 · 2022: 86 · 2021: 122 · 2020: 126 · 2019: 129 · 2018: 130 · 2017: 99 · 2016: 114 · 2015: 144 · 2014: 124 · 2013: 103 · 2012: 135
FWCI
5.42
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health (7r01gm050529-05)
  • National Institute of General Medical Sciences (GM 50529-03)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Physical Sciences › Engineering › Computational Mechanics › Ion-surface interactions and analysis
Keywords
MALDI mass spectrometry imaging, tissue section imaging, peptide localization, protein localization, pancreatic islets, pituitary peptides, rat pancreas, rat pituitary
MeSH terms
Animals, Epithelial Cells, Humans, Microscopy, Electron, Mouth Mucosa, Peptides, Proteins, Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›