The DOI matches its Crossref record.
“Turn-On” Fluorescent Sensor for Hg2+ Based on Single-Stranded DNA Functionalized Mn:CdS/ZnS Quantum Dots and Gold Nanoparticles by Time-Gated Mode
Abstract
An ultrasensitive "turn-on" fluorescent sensor was presented for determination of Hg(2+). This method is mainly based on Hg(2+)-induced conformational change of a thymine-rich single-stranded DNA. The water-soluble long-lifetime fluorescence quantum dot (Mn:CdS/ZnS) acted as the fluorophore, which was labeled on a 33-mer thymine-rich single-stranded DNA (strand A). The gold nanoparticles (GNPs) functionalized 10-mer single-stranded DNA (strand B) is selected as the quencher to quench the fluorescence of Mn:CdS/ZnS. Without Hg(2+) in the sample solution, strands A and B could form hybrid structures, resulting in the fluorescence of Mn:CdS/ZnS being decreased sharply. When Hg(2+) is present in the sample solution, Hg(2+)-mediated base pairs induced the folding of strand A into a hairpin structure, leading to the release of GNPs-tagged strand B from the hybrid structures. The fluorescence signal is then increased obviously compared with that without Hg(2+). The sensor exhibits two linear response ranges between fluorescence intensity and Hg(2+) concentration. Meanwhile, a detection limit of 0.18 nM is estimated based on 3α/slope. Selectivity experiments reveal that the fluorescent sensor is specific for Hg(2+) even with interference by high concentrations of other metal ions. This sensor is successfully applied to determination of Hg(2+) in tap water and lake water samples. This sensor offers additional advantage to efficiently reduce background noise using long-lifetime fluorescence quantum dots by a time-gated mode. With excellent sensitivity and selectivity, this sensor is potentially suitable for monitoring of Hg(2+) in environmental applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Long-Lived Emissive Probes for Time-Resolved Photoluminescence Bioimaging and Biosensing
Zhang, K. Y., Yu, Q., Wei, H., Liu, S., Zhao, Q., & Huang, W. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00425 · Cited by 923
Hildebrandt, N., Spillmann, C. M., Algar, W. R., Pons, T., Stewart, M. H., Oh, E., Susumu, K., Díaz, S. A., Delehanty, J. B., & Medintz, I. L. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00030 · Cited by 730
Doped quantum dots for chemo/biosensing and bioimaging
Wu, P., & Yan, X.-P. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60017c · Cited by 667
Noble metal nanoparticles in biosensors: recent studies and applications
Malekzad, H., Sahandi Zangabad, P., Mirshekari, H., Karimi, M., & Hamblin, M. R. (2017) · Nanotechnology Reviews · doi:10.1515/ntrev-2016-0014 · Cited by 375
Wu, P., Hou, X., Xu, J.-J., & Chen, H.-Y. (2014) · Chemical Reviews · doi:10.1021/cr400710z · Cited by 337
Metadata
- Authors
- Huang, D., Niu, C., Wang, X., Lv, X., & Zeng, G.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-01-03
- Volume
- 85
- Issue
- 2
- Pages
- 1164-1170
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2081192245
- Cited by
- 171
- References
- 0
- FWCI
- 7.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: “Turn-On” Fluorescent Sensor for Hg2+ Based on Single-Stranded DNA Functionalized Mn:CdS/ZnS Quantum Dots and Gold Nanoparticles by Time-Gated Mode. https://app.cochat.ai/papers/10.1021/ac303084d
- The paper
- Huang, D., Niu, C., Wang, X., Lv, X., & Zeng, G. (2013). “Turn-On” Fluorescent Sensor for Hg2+ Based on Single-Stranded DNA Functionalized Mn:CdS/ZnS Quantum Dots and Gold Nanoparticles by Time-Gated Mode. Analytical Chemistry. https://doi.org/10.1021/ac303084d
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.