The DOI matches its Crossref record.
Selective Diagnosis of Diabetes Using Pt-Functionalized WO3 Hemitube Networks As a Sensing Layer of Acetone in Exhaled Breath
Abstract
Thin-walled WO(3) hemitubes and catalytic Pt-functionalized WO(3) hemitubes were synthesized via a polymeric fiber-templating route and used as exhaled breath sensing layers for potential diagnosis of halitosis and diabetes through the detection of H(2)S and CH(3)COCH(3), respectively. Pt-functionalized WO(3) hemitubes with wall thickness of 60 nm exhibited superior acetone sensitivity (R(air)/R(gas) = 4.11 at 2 ppm) with negligible H(2)S response, and pristine WO(3) hemitubes showed a 4.90-fold sensitivity toward H(2)S with minimal acetone-sensing characteristics. The detection limit (R(air)/R(gas)) of the fabricated sensors with Pt-functionalized WO(3) hemitubes was 1.31 for acetone of 120 ppb, and pristine WO(3) hemitubes showed a gas response of 1.23 at 120 ppb of H(2)S. Long-term stability tests revealed that the remarkable selectivity has been maintained after aging for 7 months in air. The superior cross-sensitivity and response to H(2)S and acetone gas offer a potential platform for application in diabetes and halitosis diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Review—Non-Invasive Monitoring of Human Health by Exhaled Breath Analysis: A Comprehensive Review
Das, S., & Pal, M. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab67a6 · Cited by 466
Li, G., Cheng, Z., Xiang, Q., Yan, L., Wang, X., & Xu, J. (2019) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.09.117 · Cited by 422
Functional gas sensing nanomaterials: A panoramic view
Malik, R., Tomer, V. K., Mishra, Y. K., & Lin, L. (2020) · Applied Physics Reviews · doi:10.1063/1.5123479 · Cited by 410
Yang, G., Li, X., He, Y., Ma, J., Ni, G., & Zhou, S. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2017.12.003 · Cited by 336
Prospects and Challenges of Volatile Organic Compound Sensors in Human Healthcare
Jalal, A. H., Alam, F., Roychoudhury, S., Umasankar, Y., Pala, N., & Bhansali, S. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00400 · Cited by 315
Innovative Nanosensor for Disease Diagnosis
Kim, S.-J., Choi, S.-J., Jang, J.-S., Cho, H.-J., & Kim, I.-D. (2017) · Accounts of Chemical Research · doi:10.1021/acs.accounts.7b00047 · Cited by 264
Self-citationPeng, B., Zhao, F., Ping, J., & Ying, Y. (2020) · Small · doi:10.1002/smll.202002681 · Cited by 224
Li, T., Yin, W., Gao, S., Sun, Y., Xu, P., Wu, S., Kong, H., Yang, G., & Wei, G. (2022) · Nanomaterials · doi:10.3390/nano12060982 · Cited by 222
Electronic nose: a non-invasive technology for breath analysis of diabetes and lung cancer patients
Behera, B., Joshi, R., Anil Vishnu, G. K., Bhalerao, S., & Pandya, H. J. (2019) · Journal of Breath Research · doi:10.1088/1752-7163/aafc77 · Cited by 179
Metadata
- Authors
- Choi, S.-J., Lee, I., Jang, B.-H., Youn, D.-Y., Ryu, W.-H., Park, C. O., & Kim, I.-D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-01-07
- Volume
- 85
- Issue
- 3
- Pages
- 1792-1796
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2329751486
- Cited by
- 311
- References
- 0
- FWCI
- 9.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.