The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Colorimetric Visualization of Glucose at the Submicromole Level in Serum by a Homogenous Silver Nanoprism–Glucose Oxidase System
Abstract
In this study, we design a homogeneous system consisting of Ag nanoprisms and glucose oxidase (GOx) for simple, sensitive, and low-cost colorimetric sensing of glucose in serum. The unmodified Ag nanoprisms and GOx are first mixed with each other. Glucose is then added in the homogeneous mixture. Finally, the nanoplates are etched from triangle to round by H2O2 produced by the enzymatic oxidation, which leads to a more than 120 nm blue shift of the surface plasmon resonance (SPR) absorption band of the Ag nanoplates. This large wavelength shift can be used not only for visual detection (from blue to mauve) of glucose by naked eyes but for reliable and convenient glucose quantification in the range from 2.0 × 10(-7) to 1.0 × 10(-4) M. The detection limit is as low as 2.0 × 10(-7) M, because the used Ag nanoprisms possess (1) highly reactive edges/tips and (2) strongly tip sharpness and aspect ratio dependent SPR absorption. Owing to ultrahigh sensitivity, only 10-20 μL of serum is enough for a one-time determination. The proposed glucose sensor has great potential in the applications of point-of-care diagnostics, especially for third-world countries where high-tech diagnostics aids are inaccessible to the bulk of the population.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Colorimetric Method for Determination of Sugars and Related Substances
DuBois, M., Gilles, K. A., Hamilton, J. K., Rebers, P. A., & Smith, F. (1956) · Analytical Chemistry · doi:10.1021/ac60111a017 · Cited by 52,269
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Self-citationFluorescence-based glucose sensors
Pickup, J. C., Hussain, F., Evans, N. D., Rolinski, O. J., & Birch, D. J. S. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.10.002 · Cited by 616
Cited by
Quantum dots in biomedical applications
Wagner, A. M., Knipe, J. M., Orive, G., & Peppas, N. A. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.05.022 · Cited by 632
Shen, P., & Xia, Y. (2014) · Analytical Chemistry · doi:10.1021/ac5001338 · Cited by 596
Self-citationLocalized Surface Plasmon Resonance Biosensing: Current Challenges and Approaches
Unser, S., Bruzas, I., He, J., & Sagle, L. (2015) · Sensors · doi:10.3390/s150715684 · Cited by 565
Silver-Based Plasmonic Nanoparticles for and Their Use in Biosensing
Loiseau, A., Asila, V., Boitel-Aullen, G., Lam, M., Salmain, M., & Boujday, S. (2019) · Biosensors · doi:10.3390/bios9020078 · Cited by 503
Xu, W., Jiao, L., Yan, H., Wu, Y., Chen, L., Gu, W., Du, D., Lin, Y., & Zhu, C. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b03004 · Cited by 395
Metadata
- Authors
- Xia, Y., Ye, J., Tan, K., Wang, J., & Yang, G.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-06-10
- Volume
- 85
- Issue
- 13
- Pages
- 6241-6247
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2324962056
- Cited by
- 249
- References
- 3
- FWCI
- 9.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Colorimetric Visualization of Glucose at the Submicromole Level in Serum by a Homogenous Silver Nanoprism–Glucose Oxidase System. https://app.cochat.ai/papers/10.1021/ac303591n
- The paper
- Xia, Y., Ye, J., Tan, K., Wang, J., & Yang, G. (2013). Colorimetric Visualization of Glucose at the Submicromole Level in Serum by a Homogenous Silver Nanoprism–Glucose Oxidase System. Analytical Chemistry. https://doi.org/10.1021/ac303591n
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.