Ultrasensitive Label Free Electrical Detection of Insulin in Neat Blood Serum
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Electrical assays potentially offer a highly sensitive, cheap, portable, automated, and multiplexed means of protein biomarker detection, characteristics with an ability to underpin both disease stratification and the development of point of care diagnostics. Most conveniently applied in a reagent free manner, all sensitive assays such as these suffer, however, from profound problems when applied in complex fluids such as blood serum. We report herein, the development, and clinical application, of a highly sensitive and selective electrical insulin biosensor based on a chemisorbed zwittorionic polymer support and a novel reagentless sensing technique based on phase monitoring electrochemical impedance spectroscopy. The polymer adlayer is exceptionally effective in both reducing background response and maintaining receptive antibody binding efficacy, while the non-Faradaic analysis avoids potential interference from background electro-active molecules. Applied to the detection of even a low molecular weight protein (here, insulin), a linear range from 0.1 to 200 pM and an unprecedented femtomolar detection limit are possible in undiluted blood serum.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Anderson, N. L., & Anderson, N. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r200007-mcp200 · Cited by 4,414
A Switchable Biocompatible Polymer Surface with Self‐Sterilizing and Nonfouling Capabilities
Cheng, G., Xue, H., Zhang, Z., Chen, S., & Jiang, S. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200803570 · Cited by 371
Cited by
Antifouling Strategies for Selective In Vitro and In Vivo Sensing
Jiang, C., Wang, G., Hein, R., Liu, N., Luo, X., & Davis, J. J. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00739 · Cited by 598
Self-citationElectrical biosensors and the label free detection of protein disease biomarkers
Luo, X., & Davis, J. J. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60077g · Cited by 460
Self-citationPlasmonic nanosensors with inverse sensitivity by means of enzyme-guided crystal growth
Rodríguez-Lorenzo, L., de la Rica, R., Álvarez-Puebla, R. A., Liz-Marzán, L. M., & Stevens, M. M. (2012) · Nature Materials · doi:10.1038/nmat3337 · Cited by 443
Advances in Plasmonic Technologies for Point of Care Applications
Tokel, O., Inci, F., & Demirci, U. (2014) · Chemical Reviews · doi:10.1021/cr4000623 · Cited by 407
Paleček, E., Tkáč, J., Bartošík, M., Bertók, T., Ostatná, V., & Paleček, J. (2015) · Chemical Reviews · doi:10.1021/cr500279h · Cited by 319
Metadata
- Authors
- Luo, X., Xu, M., Freeman, C., James, T., & Davis, J. J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-03-25
- Volume
- 85
- Issue
- 8
- Pages
- 4129-4134
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2329963727
- Cited by
- 108
- References
- 2
- FWCI
- 5.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.