CoChat

Ultrasensitive Label Free Electrical Detection of Insulin in Neat Blood Serum

Luo, Xiliang, Xu, Mengyun, Freeman, Charlotte, James, Tim, Davis, Jason J. · 2013 · Analytical Chemistry
Cited by 108

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Electrical assays potentially offer a highly sensitive, cheap, portable, automated, and multiplexed means of protein biomarker detection, characteristics with an ability to underpin both disease stratification and the development of point of care diagnostics. Most conveniently applied in a reagent free manner, all sensitive assays such as these suffer, however, from profound problems when applied in complex fluids such as blood serum. We report herein, the development, and clinical application, of a highly sensitive and selective electrical insulin biosensor based on a chemisorbed zwittorionic polymer support and a novel reagentless sensing technique based on phase monitoring electrochemical impedance spectroscopy. The polymer adlayer is exceptionally effective in both reducing background response and maintaining receptive antibody binding efficacy, while the non-Faradaic analysis avoids potential interference from background electro-active molecules. Applied to the detection of even a low molecular weight protein (here, insulin), a linear range from 0.1 to 200 pM and an unprecedented femtomolar detection limit are possible in undiluted blood serum.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac4002657

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Luo, X., Xu, M., Freeman, C., James, T., & Davis, J. J.
Venue
Analytical Chemistry
Published
2013-03-25
Volume
85
Issue
8
Pages
4129-4134
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2329963727
Cited by
108
References
2
FWCI
5.79
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.