CoChat

Universal Multilayer Assemblies of Graphene in Chemically Resistant Microtubes for Microextraction

Zhang, Wenpeng, Zhang, Juan, Bao, Tao, Zhou, Wei, Meng, Jiawei, Chen, Zilin · 2013 · Analytical Chemistry
Cited by 89

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Graphene is a new kind of two-dimensional carbon nanomaterial with excellent properties and is promising for solid-phase microextraction (SPME). Plastic microtubes such as poly(tetrafluoroethylene) (PTFE) and poly(ether ether ketone) are ideal substrates for in-tube SPME. However, immobilization of graphene layers onto these materials is still a problem due to their nature of chemical resistance. In order to solve the problem, we proposed a novel method based on universal mussel-inspired polydopamine (PD) and layer-by-layer assembly of graphene in this work. To make a graphene assembly layer inside PTFE, the strategy includes two major steps. First, a PD layer is made on the PTFE surface by noncovalent interaction. Second, multilayer graphene is assembled on the PD layer by covalent interaction. By repeating these two steps, a functional graphene oxide (FGO)-modified PTFE tube with a controllable number of layers can be obtained. Morphology of the multilayer structure of graphene has been confirmed by scanning electronic microscopy. Formation of the covalent layer has also been characterized by Foourier transform infrared and X-ray photoelectron spectroscopy. It is very interesting that (FGO-PD)3-PTFE shows exceptional efficiency for SPME. Enrichment from 1082- to 2331-fold was achieved for six polyaromatic hydrocarbons (PAHs). An online SPME-HPLC-fluorescent detection method has been developed on the basis of (FGO-PD)3-PTFE. For qualitative analysis of PAHs, the method has low limits of detection of 0.05-0.1 pg/mL, which is significantly lower (up to 1000 times) than that reported in literature. The method shows wide linear range (0.3-200 pg/mL), good linearity (R(2) ≥ 0.9968), and good reproducibility (relative standard deviation < 3.4%). The method has been applied to determine PAHs in environmental samples. Good recoveries were obtained, ranging from 85.1% to 96.7%.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac401157j

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 89

Metadata

Authors
Zhang, W., Zhang, J., Bao, T., Zhou, W., Meng, J., & Chen, Z.
Venue
Analytical Chemistry
Published
2013-07-05
Volume
85
Issue
14
Pages
6846-6854
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2328079848
Cited by
89
References
1
FWCI
12.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.